MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2013.02.032

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2013

Analysis of anticoagulant rodenticide residues in Microtus arvalis tissues by liquid chromatography with diode array, fluorescence and mass spectrometry detection.

Hernández Alma M, Bernal José, Bernal José L, Martín María T, Caminero Constantino, Nozal María J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We describe here a fast and selective analytical method to determine the levels of four anticoagulant rodenticides (chlorophacinone, bromadiolone, brodifacoum and difenacoum) in animal tissues by liquid chromatography (LC) using different detection methods: fluorescence (FLD), diode array (DAD) and electrospray ionization-mass spectrometry (ESI-MS). Rodenticides were extracted from freeze-dried and homogenized tissue samples (liver, intestine and muscle) that had been obtained from the common vole (Microtus arvalis). These samples were diluted in 5 mL of methanol, the solution was shaken and centrifuged, and the supernatant was removed and evaporated to dryness. The residue was reconstituted in 1 mL of methanol (liver samples) or 1 mL of the mobile phase (muscle and intestine samples), and injected onto an LC-DAD-FLD-MS system coupled to electrospray ionization (ESI) in negative mode. After conducting an LC optimization study, we selected a Gemini 5 μm C18 column, a mobile phase composed of a mixture of 30 mM ammonium formate in water and methanol (26:74, v/v), and we used an isocratic elution mode. The method was fully validated and shown to be selective, precise, accurate, and linear in the range from ~5μg/kg (ESI-MS) or ~50 μg/kg (DAD-FLD) to 10,000 μg/kg, depending on the compound analyzed. Recoveries ranged from 82% to 103%, while the limits of detection and quantification ranged from 9-89 μg/kg (FLD-DAD) and 0.6-4.6 μg/kg (ESI-MS). This method was successfully used to simultaneously measure the aforementioned compounds in M. arvalis tissues.

Для цитирования: Hernández Alma M, Bernal José, Bernal José L, Martín María T, Caminero Constantino, Nozal María J. Analysis of anticoagulant rodenticide residues in Microtus arvalis tissues by liquid chromatography with diode array, fluorescence and mass spectrometry detection.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2013. DOI: 10.1016/j.jchromb.2013.02.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.