MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvs.2019.03.075

Медицинская библиотека · Journal of vascular surgery · 2019

Influence of artery and vein diameters on autogenous arteriovenous access patency.

Misskey Jonathan, Hamidizadeh Ramin, Faulds Jason, Chen Jerry, Gagnon Joel, Hsiang York

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Previous investigations have suggested that a minimum venous outflow diameter (MVOD) and perianastomotic arterial diameter are associated with successful autogenous arteriovenous maturation and patency. The goal of this study was to determine anatomic and clinical variables that may influence access patency to guide optimal autogenous access configuration selection.

METHODS

Accesses created from 2010 to 2016 were analyzed from data entered into a prospective database. Preprocedure duplex ultrasound mapping data of artery and tourniquet-derived vein diameters and demographic and clinical variables were collected. Survival-based cut point analysis was used to determine anatomic parameters most predictive of access failure. Kaplan-Meier and Cox proportional hazards analyses were used to assess patencies and maturation and to identify independent predictors of access failure.

RESULTS

A total of 356 first-time autogenous accesses were created (median follow-up, 20 months; range, 0-73 months). Of these, 202 (56.7%) were radiocephalic and 154 (43.3%) were brachiocephalic. Maturation failure at end of follow-up for arteriovenous accesses was 26% ± 3% for radiocephalic accesses and 15% ± 3% for brachiocephalic accesses (P < .001). For radiocephalic accesses, MVOD <3.0 mm and radial artery diameter <2.1 mm independently predicted access maturation failure (MVOD <3.0 mm: hazard ratio [HR], 2.62 [95% confidence interval (CI), 1.27-5.39; P = .009]; radial artery diameter <2.1 mm: HR, 2.20 [95% CI, 1.20-4.05; P = .011]) and secondary patency loss (MVOD <3.0 mm: HR, 2.21 [95% CI, 1.24-3.96; P = .007]; radial artery diameter <2.1 mm: HR, 2.11 [95% CI, 1.26-3.63; P = .004]). A combination of radial artery diameter <2.1 mm and MVOD <3.0 mm most strongly predicted maturation failure (HR, 4.24; 95% CI, 1.71-10.49; P = .002) and loss of secondary patency (HR, 4.03; 95% CI, 1.88-8.64; P < .001). Only diabetes mellitus (HR, 2.24; P = .012) predicted secondary patency loss. For brachiocephalic accesses, MVOD <3.4 mm (HR, 2.12; 95% CI, 1.02-4.46; P = .043) was found to independently predict secondary patency loss in addition to previous ipsilateral (HR, 2.37; P = .038) and bilateral (HR, 4.00; P = .015) tunneled hemodialysis catheters. Brachial artery diameter was not associated with either access maturation or patency.

CONCLUSIONS

Artery and tourniquet-derived vein diameters independently predict radiocephalic access patency and functional outcomes. A combination of a radial artery diameter <2.1 mm and MVOD <3.0 mm best predicts maturation failure and patency loss for radiocephalic access. MVOD <3.4 mm was associated with increased loss of brachiocephalic access secondary patency, but MVOD was not associated with maturation.

Для цитирования: Misskey Jonathan, Hamidizadeh Ramin, Faulds Jason, Chen Jerry, Gagnon Joel, Hsiang York. Influence of artery and vein diameters on autogenous arteriovenous access patency.. Journal of vascular surgery. 2019. DOI: 10.1016/j.jvs.2019.03.075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.