Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2008
[Enophthalmos correction in complex orbital floor reconstruction : computer-assisted, intraoperative, non-contact, optical 3D support].
Клинический случайАннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kühnel T V, Vairaktaris E, Schlegel K A, Neukam F W, Kühnel B, Holbach L M, Nkenke E
Аннотация
In the case of displacement of the globe such as enophthalmos induced by trauma, the patient is affected on both counts: function and aesthetics. To prevent double vision or conspicuous asymmetry, exact correction of the globe position is required. The aim of this case report is to demonstrate an intraoperative computer-assisted, non-contact, optical 3D procedure for identification of the globe position to aid in placing the eyeball in the position required in complex reconstruction of the orbital floor. A 33-year-old man presented with a sunken eye on the right side in the horizontal and vertical plane 6 months after having undergone surgery elsewhere for a zygomatico-orbital fracture, also including the orbital floor. The patient was affected by double vision and a noticeable defective globe position. In planning the correction of the globe position, a three-dimensional image of the face with opened eyes was made with the optical sensor. Automatic comparison of symmetry revealed enophthalmos of 4 mm on relative en- and exophthalmometry. The decision was made to lift the orbital floor with a split calvarial bone graft. During surgery the position of the globe was also controlled by the three-dimensional optical technique. At the end of surgery there was exophthalmos of 1 mm. Six weeks after surgery the patient was not affected by any double vision. After 3 and 24 months enophthalmos was 1 mm. This case demonstrates how the non-ionizing, non-contact, optical 3D technique can help in planning, intraoperative transformation, and clinical monitoring to identify the correct position of the corneal vertex in complex orbital floor reconstruction.
Предметные рубрики MeSH
AdultDiagnostic ImagingDiagnostic Techniques, OphthalmologicalDiplopiaEnophthalmosFacial InjuriesFracture Fixation, InternalHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMaleOrbitPostoperative ComplicationsSkiingSurgery, Computer-AssistedTomography, X-Ray ComputedUser-Computer InterfaceZygomatic Fractures