DOI 10.1053/jcrc.2002.36756

Медицинская библиотека · Journal of critical care · 2002

Noninvasive monitoring of cardiac output in human neonates and juvenile piglets by inductance cardiography (thoracocardiography).

Bloch Konrad E, Adams Jose A, Bassuk Jorge J, Mangino Martin J, Sackner Marvin A

СтатьяПеревод в очереди

Аннотация

PURPOSE: Thoracocardiography has been used in adult patients to noninvasively estimate changes in cardiac output (CO) by analysis of ventricular volume curves recorded by an inductive plethysmographic transducer encircling the chest at the level of the heart. The purpose of this study was to investigate the potential of thoracocardiography to monitor cardiac output in human neonates and in a small animal model, the juvenile piglet.

MATERIALS AND

METHODS

In 6 human premature neonates weighing 1.0 to 1.6 kg the effect of periodic respiration on CO was studied with thoracocardiography. In 9 piglets weighing 8.5 to 10.2 kg changes in CO were estimated simultaneously by thoracocardiography and thermodilution during fluid loading and rapid atrial pacing.

RESULTS

In human neonates, CO during breathing was 136% to 320% of the corresponding value during apneas. In piglets, CO by thermodilution ranged from 0.25 to 3.26 L/min. The mean difference in 40 paired estimates of relative changes in CO by thoracocardiography and thermodilution was 3%, limits of agreement (bias +/- 2 SD) were +/- 30%.

CONCLUSIONS

In neonates, increases in CO during respiratory phases of periodic breathing are consistent with expected cardiorespiratory interactions. Thoracocardiography monitored changes in CO in piglets with acceptable accuracy. Thoracocardiography holds promise for noninvasive monitoring in human neonates but further validation is required.

Для цитирования: Bloch Konrad E, Adams Jose A, Bassuk Jorge J, Mangino Martin J, Sackner Marvin A. Noninvasive monitoring of cardiac output in human neonates and juvenile piglets by inductance cardiography (thoracocardiography).. Journal of critical care. 2002. DOI: 10.1053/jcrc.2002.36756.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.