Relationship Between the Pulmonary-to-systemic-blood-flow Ratio and the Cross-sectional Area of the Right Internal Jugular Vein in Pediatric Patients With Congenital Heart Disease.

Takeshita Jun, Nakajima Yasufumi, Shimizu Yoshiyuki, Hamaba Hirofumi, Tachibana Kazuya

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To investigate the relationship between the pulmonary-to-systemic-blood-flow ratio (Qp/Qs) and the cross-sectional area (CSA) and diameter of the right internal jugular vein (RIJV) in pediatric patients with congenital heart disease using multivariate analysis.

DESIGN

Retrospective study.

SETTING

Operating room of a tertiary children's hospital.

PARTICIPANTS

Pediatric patients aged <10 years with congenital heart disease who underwent cardiovascular surgery under general anesthesia.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Multiple linear regression analyses were performed, with the CSA of the RIJV as the primary outcome and the anteroposterior and transverse diameters of the RIJV as secondary outcomes. These were designated as dependent variables, while Qp/Qs served as the independent variable. The analyses were adjusted for the following factors: weight, sex, postbidirectional Glenn operation, preoperative diuretic use, number of previous median sternotomies, single ventricle, trisomy 21, superior vena cava pressure, systolic blood pressure, heart rate, hemoglobin concentration, partial pressure of carbon dioxide, pH of arterial blood, and cardiac index. The adjusted regression coefficient estimates for Qp/Qs were as follows: 0.88 (95% confidence interval: 0.84-0.94, p < 0.001), 0.94 (95% confidence interval: 0.92-0.97, p < 0.001), and 0.94 (95% confidence interval: 0.91-0.97, p < 0.001) in the CSA, anteroposterior diameter, and transverse diameter of the RIJV, respectively.

CONCLUSIONS

A higher Qp/Qs was associated with a smaller CSA, as well as reduced anteroposterior and transverse diameters of the RIJV. Specifically, for each unit increase in Qp/Qs, the CSA of the RIJV decreased by approximately 12%.

Для цитирования: Takeshita Jun, Nakajima Yasufumi, Shimizu Yoshiyuki, Hamaba Hirofumi, Tachibana Kazuya. Relationship Between the Pulmonary-to-systemic-blood-flow Ratio and the Cross-sectional Area of the Right Internal Jugular Vein in Pediatric Patients With Congenital Heart Disease.. Journal of cardiothoracic and vascular anesthesia. 2025. DOI: 10.1053/j.jvca.2025.05.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.