MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-12341-8

Медицинская библиотека · Scientific reports · 2025

Harnessing operating room signals to estimate mean arterial pressure with AnesthNet.

Perdereau Jade, Joachim Jona, Vallée Fabrice, Cartailler Jérôme, Moreau Thomas

СтатьяПеревод в очереди

Аннотация

Monitoring mean arterial pressure (MAP) is essential for ensuring safe general anesthesia. Current practices rely either on non-invasive cuff measurements, which suffer from poor temporal resolution, or invasive arterial lines, which provide excellent accuracy and resolution but carry a significant risk of complications. Therefore, identifying alternatives to arterial lines in the operating rooms is a pressing need. Despite the importance of this issue in the community, clinically viable non-invasive MAP monitoring methods have yet to emerge. Existing approaches often encounter reproducibility issues, notably on large, open-source databases, and are not always optimized for real-time predictions. To address these limitations, this study introduces AnesthNet, a deep learning architecture designed for MAP estimation, using data exclusively from non-invasive and routine sensors such as photoplethysmography, ECG, and cuff oscillometer. AnesthNet was evaluated against the best-performing state-of-the-art deep learning architectures, using international standards to assess their performance on two of the largest datasets to date: VitalDB (2,833 patients) and LaribDB (5,060 patients). AnesthNet achieved superior performances, reaching an MAE of 4.6 (± 4.7) mmHg on VitalDB and 3.8 (± 5.7) mmHg on LaribDB. Our model also outperformed other architectures for different delays in cuff values and yielded no significant latency during inference, meeting clinical real-time requirements.

Для цитирования: Perdereau Jade, Joachim Jona, Vallée Fabrice, Cartailler Jérôme, Moreau Thomas. Harnessing operating room signals to estimate mean arterial pressure with AnesthNet.. Scientific reports. 2025. DOI: 10.1038/s41598-025-12341-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.