MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13700

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2019

Multicenter experience with the Evolution RL mechanical sheath for lead extraction using a stepwise approach: Safety, effectiveness, and outcome.

Migliore Federico, Testolina Martina, Sagone Antonio, Carretta Domenico, Agricola Tullio, Rovaris Giovanni, Piazzi Elena, Facchin Domenico, De Lazzari Manuel, Zorzi Alessandro, Melillo Francesco, Cataldi Claudia, Marzi Alessandra, Bottio Tomaso, Tarzia Vincenzo, Gerosa Gino, Iliceto Sabino, Bertaglia Emanuele, Mazzone Patrizio

Историческая статьяСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

In addition to the Evolution RL sheath, tools by Cook Medical (Bloomington, IN, USA), supporting lead extraction (LE), are available. Data on their use are not reported in detail in previous studies. Moreover, data regarding outcome are lacking. The aim was to evaluate the safety and effectiveness of the Evolution sheath (Evolution RL and Evolution Shortie, Cook Medical) by using a stepwise approach with the available extraction tools and the outcome.

METHODS

A total of 393 leads in 198 consecutive patients were removed with the Evolution RL sheath and ancillary tools using a stepwise approach.

RESULTS

The main indication for LE was infection in 125 (63.1%) cases. The mean implant duration was 95.4 ± 59.7 months. According to our stepwise approach, the Evolution Shortie RL sheath was used in all cases and complete LE was achieved in 24 (12.2%) cases. The Evolution RL was used in 174 (87.8%) cases and the SteadySheath Evolution tissue stabilization sheath (Cook Medical) in 87 (44%) because of tenacious fibrosis anchored targeted leads. Compression coil (OneTie, Cook Medical) was used in 141 (71%) cases. Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 97%, 99%, and 99.5%, respectively. One major complication (0.5%) and 10 (5%) minor complications were encountered. During a mean time follow-up of 12 ± 9 months, 14 (7%) patients died. Predictors of mortality included impaired renal function (HR 5.7; 95% CI 1.9-17.6; P = 0.002), extraction because of infection (hazard ratio [HR] 4.0; 95% confidence interval [CI] 1-18.1; P = 0.045), and diabetes (HR 3.2; 95% CI 1.1-9.8; P = 0.036).

CONCLUSIONS

Lead extraction using the Evolution RL bidirectional rotational mechanical sheath and ancillary tools in a systematic stepwise approach was effective and safe.

Для цитирования: Migliore Federico, Testolina Martina, Sagone Antonio, Carretta Domenico, Agricola Tullio, Rovaris Giovanni, Piazzi Elena, Facchin Domenico, De Lazzari Manuel, Zorzi Alessandro, Melillo Francesco, Cataldi Claudia, Marzi Alessandra, Bottio Tomaso, Tarzia Vincenzo, Gerosa Gino, Iliceto Sabino, Bertaglia Emanuele, Mazzone Patrizio. Multicenter experience with the Evolution RL mechanical sheath for lead extraction using a stepwise approach: Safety, effectiveness, and outcome.. Pacing and clinical electrophysiology : PACE. 2019. DOI: 10.1111/pace.13700.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.