MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2006.03.019

Медицинская библиотека · The Journal of hand surgery · 2006

Soft-tissue distraction with a ring external fixator before centralization for radial longitudinal deficiency.

Goldfarb Charles A, Murtha Yvonne M, Gordon J Eric, Manske Paul R

СтатьяПеревод в очереди

Аннотация

PURPOSE: To review the techniques and evaluate the use of soft-tissue distraction with a ringed fixator for radial longitudinal deficiency (RLD) before centralization.

METHODS

Eight extremities in 6 patients with severe RLD were treated with ring fixator distraction followed by centralization. A clinical examination was performed and radiographic data were obtained prospectively and at an average follow-up period of 17 months. The techniques and the early objective (range of motion, position) and radiographic outcome were evaluated.

RESULTS

The preoperative ring fixator accomplished an average of 16 mm of distraction and allowed the centralization procedure to be performed effectively and without tension. Clinical alignment was improved markedly. The hand-forearm angle improved from 72 degrees radial to 8 degrees ulnar after surgery. The volar carpal subluxation improved by an average of 6 mm.

CONCLUSIONS

Precentralization ring fixator distraction allows the performance of a tensionless centralization procedure with good early radiographic and clinical outcome in patients severely affected with RLD.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level IV.

Для цитирования: Goldfarb Charles A, Murtha Yvonne M, Gordon J Eric, Manske Paul R. Soft-tissue distraction with a ring external fixator before centralization for radial longitudinal deficiency.. The Journal of hand surgery. 2006. DOI: 10.1016/j.jhsa.2006.03.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.