Preoperative biometry data of eyes with unilateral congenital cataract.

Kun Lidia, Szigeti Andrea, Bausz Maria, Nagy Zoltan Zsolt, Maka Erika

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the differences in biometry data of eyes with unilateral congenital cataract and the contralateral normal eyes in pediatric patients.

SETTING

Pediatric Ophthalmology Division, Ophthalmology Department, Semmelweis University in Budapest, Hungary.

DESIGN

Retrospective case series.

METHODS

Data of visually significant unilateral congenital cataract patients who had cataract surgery in the ophthalmology department at Semmelweis University between 2013 and 2016 were collected. At the time of the examinations, the mean age of the patients was 36.4 weeks ± 25.3 (SD). Central corneal thickness (CCT), corneal refractive power (keratometry [K]), horizontal corneal diameter, and axial length (AL) measurement data were obtained from both eyes of each patient. The measurements were taken under general anesthesia using a handheld kerato-refractometer (Retinomax K-plus 3) and an ultrasound instrument (Ocuscan RxP) with contact applanation method and Castroviejo straight-tip calipers at the beginning of the cataract surgery. For statistical evaluation, Originlab 7.0 software was used; paired t tests were performed for the difference analysis between the 2 sides.

RESULTS

Forty-two infants (50% girls) were included. In the cases of eyes with unilateral congenital cataract, a greater CCT (P = .01330), higher average K (P = .00243), and smaller corneal diameter (P = .00010) were found, although there was no significant difference in AL when compared with the unaffected contralateral eyes.

CONCLUSION

The data showed that biometric characteristics of the eyes with unilateral congenital cataract differ from the opposite normal eye before the cataract surgery. It is essential to use this biometric data in intraocular lens power calculation and to take them into account in long-term care when screening for secondary glaucoma.

Для цитирования: Kun Lidia, Szigeti Andrea, Bausz Maria, Nagy Zoltan Zsolt, Maka Erika. Preoperative biometry data of eyes with unilateral congenital cataract.. Journal of cataract and refractive surgery. 2018. DOI: 10.1016/j.jcrs.2018.06.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.