DOI 10.3109/17453674.2013.782525
Tourniquet cuff pressure and nerve injury in knee arthroplasty in a bloodless field: a neurophysiological study.
Аннотация
BACKGROUND AND PURPOSE: Tourniquet-related nerve injuries remain a concern in orthopedic surgery. The cuff pressures used today are generally lower, and therefore a decreasing incidence of peripheral nerve injuries might also be expected. However, there have been few neurophysiological studies describing the outcome after bloodless field surgery. We describe the results of neurophysiological examinations and report the incidence of nerve injuries after total knee arthroplasty (TKA) in a bloodless field.
PATIENTS AND
METHODS
This study was part of a prospective, randomized controlled clinical trial in patients scheduled for TKA in a bloodless field. 20 consecutive patients were enrolled. Electroneurography (ENeG) and quantitative sensory testing (QST) of thermal thresholds were performed on day 3. These tests were repeated 2 months after surgery when electromyography (EMG) with a concentric-needle electrode was also performed.
RESULTS
The mean tourniquet cuff pressure was 237 (SD 33) mmHg. Electromyographic signs of denervation were found in 1 patient, who also had the highest cuff pressure in the study population (294 mmHg). The sensory nerve response amplitudes were lower in the operated leg on day 3; otherwise, the neurophysiological examinations showed no differences between the legs.
INTERPRETATION: When low tourniquet cuff pressures are used the risk of nerve injury is minor.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.