Assessment of Classical and Non-Classical Quantitative Electroencephalographic Measures in Patients with Substance Use Disorders.
Аннотация
Background
People diagnosed with substance use disorders (SUDs) are at risk for impairment of brain function and structure. However, physicians still do not have any clinical biomarker of brain impairment that helps diagnose or treat these patients when needed. The most common method to study these patients is the classical electroencephalographic (EEG) analyses of absolute and relative powers, but this has limited individual clinical applicability. Other non-classical measures such as frequency band ratios and entropy show promise in these patients. Therefore, there is a need to expand the use of quantitative (q)EEG beyond classical measures in clinical populations. Our aim is to assess a group of classical and non-classical qEEG measures in a population with SUDs.
Methods
We selected 56 non-medicated and drug-free adult patients (30 males) diagnosed with SUDs and admitted to Rehabilitation Clinics. According to qualitative EEG findings, patients were divided into four groups. We estimated the absolute and relative powers and calculated the entropy, and the alpha/(delta + theta) ratio.
Results
Our findings showed a significant variability of absolute and relative powers among patients with SUDs. We also observed a decrease in the EEG-based entropy index and alpha/(theta + delta) ratio, mainly in posterior regions, in the patients with abnormal qualitative EEG.
Conclusions
Our findings support the view that the power spectrum is not a reliable biomarker on an individual level. Thus, we suggest shifting the approach from the power spectrum toward other potential methods and designs that may offer greater clinical possibilities.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.