Evaluation of the effectiveness of the Pastormaster method for disinfection of legionella in a hospital water distribution system.

Peiró Callizo E F, Sierra J Darpón, Pombo J M Santos, Baquedano C Ezpeleta, Huerta B Pérez

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

The Pastormaster method consists of heating the water of hospital distribution systems at a specific point to a sufficient temperature for a minimum amount of time to eradicate legionella. The object of this study was to evaluate the effectiveness of the Pastormaster method for legionella disinfection in a hospital environment. A two-phase procedure was performed: hydraulic optimization of the water supply circuit, and implementation of the Pastormaster method. Water samples were taken at 10 representative points in the hospital hot-water system and cultured microbiologically. Other physical and chemical measurements were also determined. Implementation of the Pastormaster method and correction of the deficiencies identified during a hydraulic system audit confirmed the absence of legionella in the hospital water distribution system. The combination of implementation of the Pastormaster method and conduction of a hydraulic audit designed to identify and remedy any possible problems in water circulation is effective in minimizing the risk of legionella contamination in hospital water distribution systems.

Для цитирования: Peiró Callizo E F, Sierra J Darpón, Pombo J M Santos, Baquedano C Ezpeleta, Huerta B Pérez. Evaluation of the effectiveness of the Pastormaster method for disinfection of legionella in a hospital water distribution system.. The Journal of hospital infection. 2005. DOI: 10.1016/j.jhin.2004.11.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.