MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.70230

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2026

Long-Term Outcomes of 6-mm Versus 8-mm Cryoablation for Pediatric AVNRT: A Large Single-Center Study.

Karadeniz Cem, Atlan Muhammed Akif, Oksuz Sedef, Yıldız Kaan, Cirkinoglu Gozde Gursoy, Dedecengiz Hakan, Bacak Tolga, Alimoglu Berkay, Gerceker Engin, Elmalı Ferhan, Narin Nazmi

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Cryoablation is commonly used for pediatric atrioventricular nodal reentrant tachycardia (AVNRT) due to its excellent safety profile and nearly zero risk of permanent atrioventricular (AV) block. However, limited data comparing 6- and 8-mm cryocatheter tips in large pediatric cohorts are available. This study aims to evaluate and compare the procedural characteristics, acute success, and long-term outcomes of 6- and 8-mm cryoablation catheters in children undergoing slow pathway modification for AVNRT.

METHODS

We retrospectively reviewed 343 pediatric patients (≤18 years) who underwent cryoablation for AVNRT between 2016 and 2025. Patients were treated with either a 6-mm (n = 182) or an 8-mm (n = 161) cryocatheter. Baseline characteristics, electrophysiological parameters, procedural metrics, complications, and recurrence outcomes were analyzed. All procedures used three-dimensional electroanatomical mapping to improve anatomical accuracy and reduce fluoroscopy exposure.

RESULTS

Patients in the 8-mm group were older and heavier and had a higher rate of prior ablation (21.1% vs. 6.0%), indicating greater procedural complexity. Procedure duration, total cryotherapy time, and the number of lesions were significantly longer in the 8-mm group. Acute success rates were excellent in both groups (99.5% vs. 100%), and there were no cases of permanent AV block, pericardial effusion, or major complications. Over a median follow-up of 69 months in the 6-mm group and 30 months in the 8-mm group, recurrence rates were 15.4% and 10.6%, respectively (p = 0.246), showing a favorable but non-significant trend toward fewer recurrences with the 8-mm catheter.

CONCLUSION

Both 6- and 8-mm cryoablation catheters offer highly safe and effective treatment for pediatric AVNRT. Despite being used in more complex cases, the 8-mm catheter achieved comparable acute results and showed a potential long-term benefit, supporting its use in selected patient groups.

Для цитирования: Karadeniz Cem, Atlan Muhammed Akif, Oksuz Sedef, Yıldız Kaan, Cirkinoglu Gozde Gursoy, Dedecengiz Hakan, Bacak Tolga, Alimoglu Berkay, Gerceker Engin, Elmalı Ferhan, Narin Nazmi. Long-Term Outcomes of 6-mm Versus 8-mm Cryoablation for Pediatric AVNRT: A Large Single-Center Study.. Pacing and clinical electrophysiology : PACE. 2026. DOI: 10.1111/pace.70230.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.