Sound limb loading in individuals with unilateral transfemoral amputation across a range of walking velocities.

Russell Esposito Elizabeth, Aldridge Whitehead Jennifer M, Wilken Jason M

СтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Individuals with unilateral transfemoral amputation demonstrate significantly increased rates of osteoarthritis in their sound knee. This increased risk is likely the result of altered knee mechanical loading and gait compensations resulting from limited function in the prosthetic limb. Altered knee loading as calculated using loading rates and peak external knee adduction moments and impulses have been associated with both the development and progression of knee osteoarthritis in other populations. The purpose of this study was to determine if young individuals with transfemoral amputation demonstrate biomechanical indicators of increased knee osteoarthritis risk.

METHODS

Fourteen young male Service Members with unilateral transfemoral amputation and 14 able-bodied service members underwent biomechanical gait analysis at three standardized walking velocities. A two-way ANOVA (group × speed) with unpaired comparisons with Bonferroni-Holm post-hoc corrections assessed statistical significance and effect sizes (d) were calculated.

FINDINGS: Normalized peak external knee adduction moments and impulses were 25.7% (P < 0.014, d > 0.994) and 27.1% (P < 0.012, d > 1.019) lower, respectively, in individuals with trans-femoral amputation than controls when averaged across speeds, and effect sizes were large. External knee flexor moments were not, however, different between groups and effect sizes were generally small (P > 0.380, d < 0.338). Maximal loading rates were significantly greater in individuals with amputation and effect sizes were large (P < 0.001, d > 1.644).

INTERPRETATION: Individuals with transfemoral amputation did not demonstrate biomechanical risk factors for high medial compartment knee joint loads, but the increased loading rates could place the sound knee at greater risk for cartilage or other tissue damage, even if not localized to the medial compartment.

Для цитирования: Russell Esposito Elizabeth, Aldridge Whitehead Jennifer M, Wilken Jason M. Sound limb loading in individuals with unilateral transfemoral amputation across a range of walking velocities.. Clinical biomechanics (Bristol, Avon). 2015. DOI: 10.1016/j.clinbiomech.2015.09.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.