DOI 10.1182/bloodadvances.2024014143
Leech bite: a rare gynecologic emergency.
Аннотация
Up to a third of patients with hemato-oncologic conditions who have received multiply transfusions develop immune-mediated platelet transfusion refractoriness. Yet factors that influence posttransfusion platelet corrected count increments (CCI) in patients with HLA-alloimmune platelet transfusion refractoriness remain less well elucidated. Recent advances in HLA antibody characterization using fluorescent bead-based platforms enable the study of donor-specific antibody (DSA) avidity (as measured by mean fluorescence intensity [MFI]) and its impact on HLA-alloimmune platelet transfusion refractoriness. In this large retrospective study of 2012 platelet transfusions among 73 HLA-alloimmunized patients, we evaluated the impact of cumulative HLA DSA-MFI alongside other donor, platelet component, and patient characteristics on CCI at 2 and 24 hours after transfusion. As part of a quality improvement initiative, we also developed and tested a computerized algorithm to optimize donor-recipient histocompatibility based on cumulative DSA-MFI and sought other actionable predictors of CCI. In multivariate analyses, cumulative HLA DSA-MFI of ≥10 000, major/bidirectional ABO-mismatch, splenomegaly, transfusion reactions, and platelet storage in additive solution negatively affected 2-hour but not 24-hour posttransfusion CCI. The DSA-MFI threshold of 10 000 was corroborated by greater antibody-mediated complement activation and significantly more CCI failures above this threshold, suggesting the usefulness of this value to inform "permissive platelet mismatching" and to optimize CCI. Furthermore, DSA-MFI decreases were deemed feasible by the computer-based algorithm for HLA-platelet selection in a pilot cohort of 8 patients (122 transfusions) evaluated before and after algorithm implementation. When HLA-selected platelets are unavailable, ABO-identical/minor-mismatched platelet concentrates may enhance 2-hour CCI in heavily HLA-alloimmunized patients with platelet transfusion refractoriness.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.