MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2018.08.077

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2018

Outcomes after mechanical aortic valve replacement in children and young adults with congenital heart disease.

Myers Patrick O, Mokashi Suyog A, Horgan Edward, Borisuk Michele, Mayer John E, Del Nido Pedro J, Baird Christopher W

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

There are little recent data on the outcomes of mechanical aortic valve replacement (AVR) in children and young adults with congenital aortic valve disease. We sought to review the survival and associated thromboembolic or bleeding complications after mechanical AVR at a single center.

METHODS

Data were retrospectively collected for 121 patients undergoing prosthetic AVR from 2000 to 2014. Kaplan-Meier estimates and Cox proportional hazards were employed.

RESULTS

Median age at AVR was 16 years (interquartile range, 12-22.8 years). The valves implanted were the St Jude valve (St Jude Medical Inc, St Paul, Minn) in 79 patients (62%), the On-X valve (On-X Life Technologies Inc, Austin, Tex) in 45 patients (35%), and CarboMedics (Sorin SpA, Milan, Italy) in 3 patients (2.4%). Median valve size was 23 mm (range, 21-25 mm). There were 5 early deaths (3.9%). Median follow-up was 5 years (range, 1.6-9.2 years; 600 patient-years). There were 14 deaths during follow-up. Survival was 90.6% ± 2.8% at 1 year, 85.4% ± 3.7% at 5 years, and 81.5% ± 4.5% at 10 years. Freedom from aortic valve reoperation was 98% ± 1.4% at 1 and 5 years, 91.5% ± 3.9% at 7 years, and 78.4% ± 6.9% at 10 years and at latest follow-up. Univariable analysis identified younger age, lower weight, and use of a 16-mm CarboMedics valve as predictors of reoperation. Valve sizes of 16 or 17 mm have a significantly higher risk of reoperation compared with larger valves (log-rank test, P < .001). At multivariable analysis, only younger age was a significant independent predictor of reoperation (hazard ratio, 0.84; 95% confidence interval, 0.71-0.99; P = .038). All patients were treated with warfarin to a goal international normalized ratio of 2.0 to 3.0. Four patients (3.1%; 0.66% per patient-year) had thromboembolic complications, and 5 patients (3.9%; 0.83% per patient-year) had bleeding events during follow-up.

CONCLUSIONS

Mechanical AVR in patients with congenital heart disease has excellent short- and midterm outcomes. Younger age was an independent predictor of reoperation.

Для цитирования: Myers Patrick O, Mokashi Suyog A, Horgan Edward, Borisuk Michele, Mayer John E, Del Nido Pedro J, Baird Christopher W. Outcomes after mechanical aortic valve replacement in children and young adults with congenital heart disease.. The Journal of thoracic and cardiovascular surgery. 2018. DOI: 10.1016/j.jtcvs.2018.08.077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.