DOI 10.1016/j.seizure.2026.05.008
Comparison of postoperative recovery indicators between stereoelectroencephalography and subdural grid electrode implantation for drug-resistant epilepsy.
Аннотация
OBJECTIVE
In intracranial electrode implantation for drug-resistant epilepsy (DRE), stereoelectroencephalography (SEEG) has increasingly been adopted as a less invasive alternative to subdural grid (SDG) implantation; however, its impact not only on surgical safety outcomes but also on the actual postoperative recovery course remains insufficiently studied. This study compared postoperative recovery indicators between SDG and SEEG.
METHODS
We retrospectively analyzed consecutive patients who underwent SDG or SEEG for DRE. Nine postoperative recovery outcomes were compared by univariable analysis: operation time, blood loss, time to adequate oral intake, number of analgesic administrations, number of antiemetic administrations, time to urinary catheter removal, time to body temperature normalization, time to white blood cell count normalization, and time to C-reactive protein normalization. In addition, exploratory multivariable regression analyses adjusted for age, sex, and year of procedure were performed.
RESULTS
Participants comprised 47 patients (SDG, n = 23; SEEG, n = 24). In the univariable analysis, the SEEG group showed lower blood loss, earlier resumption of oral intake, fewer antiemetic administrations, shorter time to urinary catheter removal, and shorter time to WBC normalization. In the exploratory multivariable regression analyses, SEEG was significantly associated with reduced blood loss (p = 0.0022), shorter time to adequate oral intake (p = 0.0024), and fewer antiemetic administrations (p = 0.0134), and these associations remained significant after false discovery rate correction.
CONCLUSIONS
Compared with SDG, SEEG was associated with reduced blood loss, earlier resumption of oral intake, and fewer antiemetic administrations. These findings suggest that SEEG may offer early postoperative recovery after intracranial electrode implantation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.