DOI 10.1053/j.jvca.2022.06.038
Perioperative Outcomes in Patients With Failing Single-Ventricle Physiology Undergoing Ventricular Assist Device Placement: A Single Institutional Experience.
Аннотация
OBJECTIVE
To address the current lack of specified data existing regarding the perioperative characteristics and outcomes in a novel patient population, which may bridge the current understanding of how patient characteristics and perioperative management may influence the postoperative hospital course before cardiac transplantation.
DESIGN
A retrospective electronic chart review included all patients with failing single- ventricle (SV) physiology receiving ventricular assist device (VAD) support at a high-volume pediatric VAD center between April 5, 2010, and December 1, 2020, using institution-based electronic medical records for retrospective analysis.
SETTING
At a single pediatric hospital.
PARTICIPANTS
Fourteen pediatric patients with failing SV physiology receiving ventricular assist device therapy (SVAD).
INTERVENTIONS: None.
MEASUREMENTS AND MAIN
RESULTS
Preoperative, intraoperative, and postoperative patient demographic and medical data were obtained from prior inpatient progress notes, laboratory values, anesthetic records, cardiac catheterization reports, echocardiography reports, and postoperative surgical notes entered during inpatient encounters at the time of SVAD placement. Between April 5, 2010, and December 1, 2020, 16 VAD device implants supported 14 pediatric patients with failing SV physiology. Most patients presented with a preoperative diagnosis of hypoplastic left heart syndrome (N = 9, 64.3%). A total of 6 patients expired on VAD therapy (43%), 7 (50%) survived to receive a cardiac transplant, and 1 patient currently remains on device therapy.
CONCLUSION
Although our institutional approach represents a single perspective, we anticipate that our experience institutional experience may prove helpful to others caring for peditric patients with single ventricle physiology undergoing ventricular assist device placement and promote collaborative efforts to improve their care.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление