MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/01.neu.0000369654.41677.b7

Медицинская библиотека · Neurosurgery · 2010

Transcranial electrocortical stimulation to monitor the facial nerve motor function during cerebellopontine angle surgery.

Acioly Marcus André, Liebsch Marina, Carvalho Carlos Henrique, Gharabaghi Alireza, Tatagiba Marcos

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study was conducted to investigate the success rate of using the facial motor evoked potential (FMEP) of orbicularis oculi and oris muscles for facial nerve function monitoring with use of a stepwise protocol, and its usefulness in predicting facial nerve outcome during cerebellopontine angle (CPA) surgeries.

METHODS

FMEPs were recorded intraoperatively from 60 patients undergoing CPA surgeries. Transcranial electrocortical stimulation (TES) was performed using corkscrew electrodes positioned at hemispheric montage (C3/C4 and CZ). The contralateral abductor pollicis brevis muscle was used as the control response. Stimulation was always applied contralaterally to the affected side using 1, 3, or 5 rectangular pulses ranging from 200 to 600 V with 50 micros of pulse duration and an interstimulus interval of 2 ms. Facial potentials were recorded from needles placed in the orbicularis oculi and oris muscles.

RESULTS

FMEP from the orbicularis oris and oculi muscles could be reliably monitored in 86.7% and 85% of the patients, respectively. The immediate postoperative facial function correlated significantly with the FMEP ratio in the orbicularis oculi muscle at 80% amplitude ratio (P = .037) and orbicularis oris muscle at 35% ratio (P = .000). FMEP loss was always related to postoperative facial paresis, although in different degrees.

CONCLUSION

FMEPs can be obtained reliably by using TES with 3 to 5 train pulses. Stable intraoperative FMEPs can predict a good postoperative outcome of facial function. However, further refinements of this technique are necessary to minimize artifacts and to make this method more reliable.

Для цитирования: Acioly Marcus André, Liebsch Marina, Carvalho Carlos Henrique, Gharabaghi Alireza, Tatagiba Marcos. Transcranial electrocortical stimulation to monitor the facial nerve motor function during cerebellopontine angle surgery.. Neurosurgery. 2010. DOI: 10.1227/01.neu.0000369654.41677.b7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.