MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2025.04.008

Медицинская библиотека · American journal of infection control · 2025

The impact of an air sanitizer spray on the risk of virus transmission by aerosols generated by toilet flushing.

Boone Stephanie A, Betts-Childress Nicklous D, Ijaz M Khalid, McKinney Julie, Gerba Charles P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Toilet flushing has been reported to result in pathogen contamination of restroom fomites and air. The goal of this study was to investigate the effectiveness of an air sanitizing spray on reducing cross-contamination of restroom fomites and air after toilet flushing.

METHODS

Bacteriophage MS2 was added to toilet bowl water, then flushed, and cross-contamination of restroom fomites and air was determined. Subsequently, the procedure was replicated to determine the interventional role of using either an air sanitizer spray or surface disinfectant spray after toilet flushing.

RESULTS

A 90 to 99.99% reduction of cross-contamination on fomites occurred with the use of the air sanitizer, depending on the fomite location and sanitizer spray duration. Use of the air sanitizer significantly reduced viral contamination only on the toilet seat after spraying for 8 seconds, but after a 30-second spray, cross-contamination was significantly reduced on 4 of 5 restroom surfaces. Air contamination was also reduced by almost 99% after the use of air sanitizer. In contrast, when a hard surface disinfectant spray was sprayed in the air, its impact on post-flushing cross-contamination of surfaces was negligible.

CONCLUSIONS

The air sanitizer significantly reduced airborne pathogen exposure from toilet flushing, including the risk of norovirus transmission in the restroom.

Для цитирования: Boone Stephanie A, Betts-Childress Nicklous D, Ijaz M Khalid, McKinney Julie, Gerba Charles P. The impact of an air sanitizer spray on the risk of virus transmission by aerosols generated by toilet flushing.. American journal of infection control. 2025. DOI: 10.1016/j.ajic.2025.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.