MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of family practice · 1994

Anesthetic blocks for loop electrosurgical excision procedure.

Harper D M, Walstatter B S, Lofton B J

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Various types of anesthetic blocks have been used to prevent pain during ambulatory gynecologic surgery. The purpose of this study was to compare the pain and cramping perceived by patients during the loop electrosurgical excision procedure when intramucosal or distal paracervical blocks were used.

METHODS

Seventy-seven women consented to participate in the prospective clinical trial. All women were premedicated with a nonsteroidal anti-inflammatory drug. Immediately after the procedure, a trained interviewer, blinded to the type of anesthetic block, recorded the patient's perceptions of pain and cramping caused by the procedure. Age, parity, marital status, lesion severity, loop size used, number of specimens, amount of bleeding, method of hemostasis, and thermal artifact were included on the analysis.

RESULTS

On a Likert scale in which 0 = no pain/cramping and 10 = worst pain/cramping, the median pain score was 3 for the distal paracervical block and 4 for the intramucosal block. The median cramping scores were 3 and 2, respectively. Pain and cramping scores did not differ significantly between the two block cohorts. The demographic and procedural variables did not predict the perception of pain or cramping. Most (89.6%) of the study population experienced pain, whereas fewer (64.9%) experienced cramping. Subjects reported significantly less cramping than pain, irrespective of the anesthetic block used (chi 2 = 13.35, P = .0003).

CONCLUSIONS

There is no difference in the perceptions of pain and cramping resulting from the loop electrosurgical excision procedure between patients receiving an intramucosal block and those receiving a distal paracervical block. There is minimal pain and cramping associated with the procedure.

Для цитирования: Harper D M, Walstatter B S, Lofton B J. Anesthetic blocks for loop electrosurgical excision procedure.. The Journal of family practice. 1994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.