Assessment of the anterior chamber angle in patients with nanophthalmos: an anterior segment optical coherence tomography study.

Kara Necip, Baz Okkes, Altinkaynak Hasan, Altan Cigdem, Demirok Ahmet

Клиническое исследованиеСравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To quantitatively assess the parameters of anterior chamber and angle dimensions by anterior segment optical coherence tomography (AS-OCT) in nanophthalmos.

METHODS

In this prospective, cross-sectional and comparative study, 34 eyes of 34 healthy individuals (control group) and 37 eyes of 37 patients with nanophthalmos (study group) were enrolled. A single experienced ophthalmologist imaged and measured the right eye with the Visante AS-OCT. The anterior chamber angle (ACA), angle opening distance (AOD) at 500 and 750 µm from the scleral spur, and trabecular-iris space area (TISA) at 500 and 750 µm at the nasal and temporal angles were measured.

RESULTS

Mean nasal/temporal ACA was 44.90 ± 9.09/47.07 ± 8.69° in the control group and 32.15 ± 10.30/29.77 ± 10.57° in the study group (p < 0.001). Mean nasal/temporal AOD500 and AOD750 was 0.52 ± 0.18/0.53 ± 0.15 mm and 0.71 ± 0.26/0.71 ± 0.23 mm in the control group. The mean nasal/temporal AOD500 and AOD750 were 0.33 ± 0.12/0.31 ± 0.15 mm and 0.48 ± 0.16/0.47 ± 0.22 mm in the study group. Mean nasal/temporal TISA500 and TISA750 were 0.16 ± 0.06/0.17 ± 0.05 mm(2) and 0.31 ± 0.11/0.33 ± 0.09 mm(2) in the control group. Mean nasal/temporal TISA500 and TISA750 were 0.11 ± 0.04/0.09 ± 0.05 mm(2) and 0.20 ± 0.07/0.20 ± 0.10 mm(2) in the study group. All values were significantly lower in the study group compared with the control group.

CONCLUSION

Determination of angle parameters using AS-OCT is a rapid noncontact method that is useful in patients with nanophthalmos. The findings demonstrated that nanophthalmic eyes had lower ACA parameters including ACA, AOD500, AOD750, TISA500 and TISA750 at the nasal and temporal angles.

Для цитирования: Kara Necip, Baz Okkes, Altinkaynak Hasan, Altan Cigdem, Demirok Ahmet. Assessment of the anterior chamber angle in patients with nanophthalmos: an anterior segment optical coherence tomography study.. Current eye research. 2013. DOI: 10.3109/02713683.2013.774025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.