MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/ane.0000000000002656

Медицинская библиотека · Anesthesia and analgesia · 2018

Improvement of the Elevated Tryptase Criterion to Discriminate IgE- From Non-IgE-Mediated Allergic Reactions.

Gastaminza Gabriel, Lafuente Alberto, Goikoetxea Maria Jose, D'Amelio Carmen M, Bernad-Alonso Amalia, Vega Olga, Martinez-Molina Juan Ambrosio, Ferrer Marta, Nuñez-Cordoba Jorge M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Differentiating between immunoglobulin E (IgE)-dependent and IgE-independent hypersensitivity reactions may improve the etiologic orientation and clinical management of patients with allergic reactions in the anesthesia setting. Serum tryptase levels may be useful to discriminate the immune mechanism of allergic reactions, but the diagnostic accuracy and optimal cutpoint remain unclear.We aimed to compare the diagnostic accuracy of tryptase during reaction (TDR) alone and the TDR/basal tryptase (TDR/BT) ratio for discriminating IgE- from non-IgE-mediated allergic reactions, and to estimate the best cut point for these indicators.

METHODS

We included 111 patients (45% men; aged 3-99 years) who had experienced an allergic reaction, even though the allergic reaction could be nonanaphylactic. Allergy tests were performed to classify the reaction as an IgE- or non-IgE-mediated one. The area under the curve (AUC) of the receiver operating characteristic analysis was performed to estimate the discriminative ability of TDR and TDR/BT ratio.

RESULTS

An IgE-mediated reaction was diagnosed in 49.5% of patients, and 56% of patients met anaphylaxis criteria. The median (quartiles) TDR for the IgE-mediated reactions was 8.0 (4.9-19.6) and 5.1 (3.5-8.1) for the non-IgE-mediated (P = .022). The median (quartiles) TDR/BT ratio was 2.7 (1.7-4.5) in IgE-mediated and 1.1 (1.0-1.6) in non-IgE-mediated reactions (P < .001). The TDR/BT ratio showed the greatest ability to discriminate IgE- from non-IgE-mediated reactions compared to TDR (AUC TDR/BT = 0.79 [95% confidence interval (CI), 0.70-0.88] and AUC TDR = 0.66 [95% CI, 0.56-0.76]; P = .001). The optimal cut point for TDR/BT (maximization of the sum of the sensitivity and specificity) was 1.66 (95% CI, 1.1-2.2).

CONCLUSIONS

The TDR/BT ratio showed a significantly better discriminative ability than TDR to discriminate IgE- from non-IgE-mediated allergic reactions. An optimal TDR/BT ratio threshold of approximately 1.66 may be useful in clinical practice to classify allergic reactions as IgE- or non-IgE-mediated.

Для цитирования: Gastaminza Gabriel, Lafuente Alberto, Goikoetxea Maria Jose, D'Amelio Carmen M, Bernad-Alonso Amalia, Vega Olga, Martinez-Molina Juan Ambrosio, Ferrer Marta, Nuñez-Cordoba Jorge M. Improvement of the Elevated Tryptase Criterion to Discriminate IgE- From Non-IgE-Mediated Allergic Reactions.. Anesthesia and analgesia. 2018. DOI: 10.1213/ane.0000000000002656.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.