DOI 10.1016/j.ijcard.2018.04.042

Медицинская библиотека · International journal of cardiology · 2018

Mechanical prosthetic heart valves: Quality of anticoagulation and thromboembolic risk. The observational multicenter PLECTRUM study.

Poli Daniela, Antonucci Emilia, Pengo Vittorio, Migliaccio Ludovica, Testa Sophie, Lodigiani Corrado, Coffetti Nadia, Facchinetti Roberto, Serricchio Giuseppina, Falco Pietro, Mangione Catello, Masottini Serena, Ruocco Lucia, De Caterina Raffaele, Palareti Gualtiero, Italian Federation of Anticoagulation Clinics

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Patients with a mechanical prosthetic heart valve implantation need to be treated with a vitamin K antagonist (VKA) due to a substantially high risk of thromboembolism. In this study we report data on patients with mechanical heart valves (MV), with the aim of evaluating the thromboembolic risk in relation to the type and site of implantation, quality of anticoagulation and risk factors associated with thromboembolism.

METHODS

Observational retrospective multicenter study among Centers affiliated to the Italian Federation of Anticoagulation Clinics (FCSA) on patients with MV implanted after 1990 and followed for the management of anticoagulation.

RESULTS

We analyzed 2357 patients with mechanical heart valves (55.2% males), followed for 24,081 years. During the follow-up, 164 thromboembolic events (0.67/100 pt-yrs) and 243 major bleedings (1.0/100 pt-yrs) occurred. The median Time in Therapeutic Range (TTR), calculated in all intended INR classes, was 60% (IQR 47-74%). The rates of thrombotic events were significantly higher in patients intended to stay at therapeutic ranges >INR 2.0-3.0. The presence of atrial fibrillation, history of thromboembolism and of mitral prosthesis were independently associated with thromboembolism. However, a bad quality of anticoagulation (TTR <47%, 25°percentile of our population) was not correlated with thromboembolism.

CONCLUSIONS

A low rate of bleeding and thromboembolic events in patients with mechanical heart valves were found, despite the sub-optimal anticoagulation control. The thromboembolic risk was not associated with the low TTR.

Для цитирования: Poli Daniela, Antonucci Emilia, Pengo Vittorio, Migliaccio Ludovica, Testa Sophie, Lodigiani Corrado, Coffetti Nadia, Facchinetti Roberto, Serricchio Giuseppina, Falco Pietro, Mangione Catello, Masottini Serena, Ruocco Lucia, De Caterina Raffaele, Palareti Gualtiero, Italian Federation of Anticoagulation Clinics. Mechanical prosthetic heart valves: Quality of anticoagulation and thromboembolic risk. The observational multicenter PLECTRUM study.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.04.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.