MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina62081507

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2026

Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.

Rudžianskas Viktoras, Jaselskė Evelina, Laurikaitienė Jurgita, Šimonytė-Verbickienė Vita, Adlienė Diana

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

Background and

Objectives

Early-stage glottic cancer requires highly precise radiotherapy due to laryngeal motion and the proximity of critical structures. Magnetic resonance-guided radiotherapy (MRgRT) enables real-time visualization and motion management, potentially improving dose conformity while reducing treatment margins. This pilot comparative planning study compared the dosimetric characteristics of MR-guided intensity-modulated radiotherapy (IMRT) delivered on the Unity MR-linac with volumetric modulated arc therapy (VMAT) plans generated for the TrueBeam STx and Halcyon systems. Materials and

Methods

Ten patients with T1-T2N0 glottic squamous cell carcinoma were included. For each patient, treatment plans prescribing 42.5 Gy in five fractions were generated using all three systems. Planning target volume (PTV) coverage, conformity index (CI), homogeneity index (HI), organ-at-risk (OAR) doses, monitor units, and beam-on times were compared using Friedman and post hoc Wilcoxon signed-rank tests.

Results

Unity achieved superior dose conformity (CI 0.97 ± 0.01 vs. 0.78 ± 0.15 for TrueBeam STx and 0.58 ± 0.19 for Halcyon; p < 0.001) and the highest mean dose, while PTV coverage (D95% and D98%) was comparable to TrueBeam STx and higher than Halcyon. Reduced treatment margins resulted in significantly smaller PTV volumes (11.09 ± 3.87 cm3 vs. 17.43 ± 4.75 cm3; p = 0.0001). Halcyon demonstrated the most homogeneous dose distribution (HI 7.88 ± 3.14), whereas TrueBeam STx showed intermediate homogeneity (HI 12.81 ± 3.90). Most OAR dose metrics were comparable among techniques, although selected laryngeal structures and the esophagus differed significantly. Beam-on time was longest for Unity.

Conclusions

MR-guided IMRT provided superior dose conformity while maintaining target coverage comparable to TrueBeam STx with clinically acceptable OAR sparing. Prospective clinical studies are required to determine whether these dosimetric advantages translate into improved patient outcomes.

Для цитирования: Rudžianskas Viktoras, Jaselskė Evelina, Laurikaitienė Jurgita, Šimonytė-Verbickienė Vita, Adlienė Diana. Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.. Medicina (Kaunas, Lithuania). 2026. DOI: 10.3390/medicina62081507.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.