MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2017.12.011

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2017

Preservation of conductive propagation after surgical repair of cardiac defects with a bio-engineered conductive patch.

He Sheng, Song Huifang, Wu Jun, Li Shu-Hong, Weisel Richard D, Sung Hsing-Wen, Li Jianding, Li Ren-Ke

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Both stable and biodegradable biomaterials have been used to surgically repair congenital cardiac defects. However, neither type of biomaterial can conduct electrical activity. We evaluated the conductivity and efficacy of a newly synthesized conductive polypyrrole-chitosan (Ppy+Chi) gelfoam patch to support cardiomyocyte (CM) viability and function in vitro and to surgically repair a cardiac defect in vivo.

METHODS

Ppy+Chi was incorporated into gelfoam (Gel) to form a 3-dimensional conductive patch. In vitro, patch characteristics were evaluated and biocompatibility and bioconductivity were investigated by culturing neonatal rat CMs on the patches. In vivo, a full-thickness right ventricular outflow tract defect was created in rats and the patches were implanted. Four weeks after patch repair, cardiac electrical activation and conduction velocity were evaluated using an optical mapping system.

RESULTS

In vitro, the Ppy+Chi+Gel patch had a higher mean breaking stress than the Gel or Chi+Gel patches, and the highest conductivity. None of the patches altered cell growth. The Ca2+ transient velocity of CMs cultured on the Ppy+Chi+Gel patch was 2.5-fold higher than that of CMs cultured on the Gel or Chi+Gel patches. In vivo, optical mapping at 4 weeks post-implantation demonstrated that Ppy+Chi+Gel patch-implanted hearts had faster conduction velocities, as measured on the epicardial surface. Continuous electrocardiographic telemetry did not reveal any pathologic arrhythmias after patch implantation. Ex-vivo patch conductivity testing also revealed that the Ppy+Chi+Gel patch was more conductive than the Gel and Chi+Gel patches.

CONCLUSIONS

The Ppy+Chi+Gel patch was biocompatible, safe and conductive, making it an attractive candidate for a new biomaterial platform for cardiac surgical repair to preserve synchronous ventricular contraction.

Для цитирования: He Sheng, Song Huifang, Wu Jun, Li Shu-Hong, Weisel Richard D, Sung Hsing-Wen, Li Jianding, Li Ren-Ke. Preservation of conductive propagation after surgical repair of cardiac defects with a bio-engineered conductive patch.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2017. DOI: 10.1016/j.healun.2017.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.