Müller Marlene, Biermann Daniel, Righa Miriam Mkanyika, Carstens Henning, Kozlik-Feldmann Rainer Gerhard, Hübler Michael, Sachweh Jörg Siegmar
Аннотация
BACKGROUND: In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated.
METHOD: Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD).
RESULTS: The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007).
CONCLUSION: A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.
METHOD: Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD).
RESULTS: The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007).
CONCLUSION: A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.
Предметные рубрики MeSH
HumansPulmonary ValveMaleFemaleAdultYoung AdultHeart Valve Prosthesis ImplantationTime FactorsMiddle AgedAdolescentHeart Valve ProsthesisInfantRisk FactorsTreatment OutcomeChildProsthesis DesignChild, PreschoolBioprosthesisTetralogy of FallotRetrospective StudiesAge FactorsProsthesis FailureRisk AssessmentReoperation