m+Medelevator.RU
← Поиск публикаций
Obstetrics and gynecology · 2014

Predictive value of cervical length measurement and fibronectin testing in threatened preterm labor.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

van Baaren Gert-Jan, Vis Jolande Y, Wilms Femke F, Oudijk Martijn A, Kwee Anneke, Porath Martina M, Oei Guid, Scheepers Hubertina C J, Spaanderman Marc E A, Bloemenkamp Kitty W M, Haak Monique C, Bolte Antoinette C, Bax Caroline J, Cornette Jérôme M J, Duvekot Johannes J, Nij Bijvanck Bas W A, van Eyck Jim, Franssen Maureen T M, Sollie Krystyna M, Vandenbussche Frank P H A, Woiski Mallory, Grobman William A, van der Post Joris A M, Bossuyt Patrick M M, Opmeer Brent C, Mol Ben W J

Аннотация

OBJECTIVE: To estimate the performance of combining cervical length measurement with fetal fibronectin testing in predicting delivery in women with symptoms of preterm labor.

METHODS: We conducted a prospective nationwide cohort study in all 10 perinatal centers in The Netherlands. Women with symptoms of preterm labor between 24 and 34 weeks of gestation with intact membranes were included. In all women, qualitative fibronectin testing (0.050-microgram/mL cutoff) and cervical length measurement were performed. Logistic regression was used to predict spontaneous preterm delivery within 7 days after testing. A risk less than 5%, corresponding to the risk for women with a cervical length of at least 25 mm, was considered as low risk.

RESULTS: Between December 2009 and August 2012, 714 women were enrolled. Fibronectin results and cervical length were available for 665 women, of whom 80 (12%) delivered within 7 days. Women with a cervical length of at least 30 mm or with a cervical length between 15 and 30 mm with a negative fibronectin result were at low risk (less than 5%) of spontaneous delivery within 7 days. Fibronectin testing in case of a cervical length between 15 and 30 mm additionally classified 103 women (15% of the cohort) as low risk and 36 women (5% of the cohort) as high risk.

CONCLUSION: Cervical length measurement, combined with fetal fibronectin testing in case of a cervical length between 15 and 30 mm, improves identification of women with a low risk to deliver spontaneously within 7 days.

LEVEL OF EVIDENCE: II.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты