MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2026.01.025

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2026

Heparin Exposure Adjustment to Reduce Thrombo-hemorrhagic Complications After Venoarterial Extracorporeal Membrane Oxygenator Cannulation: The HEART-ECMO Observational Cohort Study.

Redondo Emilio Arbas, Rodríguez Sandra Ofelia Rosillo, Rodrigo Clara Ugueto, Codón Juan Caro, Romero Eduardo Armada, Román Alfonso Jurado, García Guillermo Galeote, Valero Santiago Jiménez, Márquez Daniel Tébar, Colunga Pablo Merás, Cantador José Ruiz, Argos Carlos Merino, Chaverri Adriana Rodríguez, de Antonio Inés Ponz, Maldonado Carlos González, Torres Ervigio Corral, Gómez José Raúl Moreno

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Hemorrhagic complications remain a major concern in patients with cardiogenic shock and extracorporeal cardiopulmonary resuscitation. The purpose of this study was to assess the effect of withholding a bolus of unfractionated heparin (UFH) during emergent cannulation of the peripheral venoarterial extracorporeal membrane oxygenator (VA-ECMO) on initial coagulation parameters, and its association with bleeding and thrombotic complications.

DESIGN AND

SETTING

Retrospective, single-center, observational study.

PARTICIPANTS AND INTERVENTIONS: Adult patients undergoing emergent peripheral VA-ECMO were stratified by receipt of an intravenous UFH bolus at the time of cannulation. Then, systemic UFH perfusion was initiated unless contraindicated.

MEASUREMENTS AND MAIN

RESULTS

A total of 59 patients were included in the analysis between 2020 and 2024. Mean activated partial thromboplastin time did not differ between groups, with comparable proportions of values within the therapeutic range (15.2% in the bolus group v 13.3% in the nonbolus group; p = 0.776). Major bleeding (Bleeding Academic Research Consortium classification ≥3) within the first 24 hours was more frequent in the UFH bolus group (42.9% v 25.0%) and was associated with a greater need for red blood cell transfusions (median 4 v 2 units; p = 0.003). Multivariate analysis showed similar trends (adjusted odds ratio: 2.26; p = 0.311). Thrombotic event rates were similar between groups (14.3% v 16.7%; p = 0.803), and no device-related thrombosis was observed.

CONCLUSIONS

Withholding the UFH bolus during VA-ECMO cannulation results in comparable postimplantation activated partial thromboplastin time values and may reduce early bleeding without increasing thrombotic complications. This limited heparin exposure strategy appears safe and warrants further evaluation in randomized controlled studies.

Для цитирования: Redondo Emilio Arbas, Rodríguez Sandra Ofelia Rosillo, Rodrigo Clara Ugueto, Codón Juan Caro, Romero Eduardo Armada, Román Alfonso Jurado, García Guillermo Galeote, Valero Santiago Jiménez, Márquez Daniel Tébar, Colunga Pablo Merás, Cantador José Ruiz, Argos Carlos Merino, Chaverri Adriana Rodríguez, de Antonio Inés Ponz, Maldonado Carlos González, Torres Ervigio Corral, Gómez José Raúl Moreno. Heparin Exposure Adjustment to Reduce Thrombo-hemorrhagic Complications After Venoarterial Extracorporeal Membrane Oxygenator Cannulation: The HEART-ECMO Observational Cohort Study.. Journal of cardiothoracic and vascular anesthesia. 2026. DOI: 10.1053/j.jvca.2026.01.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.