Corneal biomechanical properties and intraocular pressure measurement in patients with nanophthalmos.

Altan Cigdem, Kara Necip, Baz Okkes, Satana Banu, Demirok Ahmet, Yilmaz Omer Faruk

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIMS: To compare the biomechanical properties of the cornea and intraocular pressure (IOP) between patients with nanophthalmos and age-matched controls.

METHODS

In this prospective, cross-sectional and comparative study, 27 eyes of 27 healthy individuals (control group) and 27 eyes of 27 patients with nanophthalmos (study group) were enrolled. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated intraocular pressure (IOPcc) and Goldmann correlated intraocular pressure (IOPg) were recorded for the right eye of each participant using Reichert Ocular Response Analyser measurements. Also, all participants in this study underwent a standardised ocular examination including IOP measurement with Goldmann applanation tonometry (IOP(GAT)), central corneal thickness and axial length (AL) assessments.

RESULTS

Mean CH in the nanophthalmic eyes and in the control eyes were 13.3 ± 2.4 mm Hg and 11.6 ± 1.7 mm Hg, respectively (p=0.003); mean CRF values in the nanophthalmic and the control eyes were 13.2 ± 1.8 mm Hg and 11.4 ± 1.9 mm Hg, respectively (p=0.001). Mean IOP(GAT) was 15.2 ± 3.3 mm Hg in the nanophthalmic eyes and 13.4 ± 2.7 mm Hg in the control group (p=0.031); mean IOPg values for the nanophthalmic and the control groups were 17.1 ± 5.3 mm Hg and 14.7 ± 3.5 mm Hg, respectively (p=0.042). Mean IOPcc values in the nanophthalmic and the control group were 13.6 ± 6.1 mm Hg and 14.8 ± 3.2 mm Hg, respectively (p=0.365).

CONCLUSION

The CH, CRF, IOPg and IOP(GAT) were significantly higher in the nanophthalmic eyes, whereas no significant differences in IOPcc were observed. These findings may be taken into account when measuring IOP values in patients with nanophthalmos.

Для цитирования: Altan Cigdem, Kara Necip, Baz Okkes, Satana Banu, Demirok Ahmet, Yilmaz Omer Faruk. Corneal biomechanical properties and intraocular pressure measurement in patients with nanophthalmos.. The British journal of ophthalmology. 2012. DOI: 10.1136/bjophthalmol-2011-300557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.