DOI 10.1016/j.ijporl.2025.112239
Infection rate following mandibular distraction with internal and external devices in infants.
Аннотация
BACKGROUND
Internal and external devices may be utilized in mandibular distraction osteogenesis (MDO) for the correction of symptomatic micrognathia in infants and children.
PURPOSE: To compare the rate and severity of infection between internal and external MDO devices.
STUDY DESIGN, SETTING, SAMPLE: Retrospective cohort study utilizing an institutional database of patients who underwent MDO.
INDEPENDENT VARIABLE: Use of internal versus external MDO hardware.
MAIN OUTCOME VARIABLES: Rate of post-operative surgical site infections (minor and major).
COVARIATES: Patient age, device type, laterality, infection, and treatment were documented.
ANALYSIS: Chi-Square and Fisher Exact Tests were used where appropriate for categorical variables and two-tailed T-tests were used for continuous variables. Significance was set at p < 0.05.
RESULTS
Between 2010 and 2022, 36 infants (ages 7 days-12 months) underwent bilateral MDO. Thirteen cases utilized internal hardware (n = 26 surgical sites) and 23 cases utilized external hardware (n = 46 surgical sites). Fifteen patients developed post-operative infections (41.7 %), 11 of which were minor infections and 4 were major infections. Seven patients with internal devices (53.8 %) and 8 patients with external devices (34.8 %) developed an infection (p = 0.27). Minor infections occurred in 4 patients with internal hardware (30.8 %) and 7 patients with external hardware (30.4 %; p = 1.00). Major infections occurred in 3 patients with internal hardware (23.1 %) and 1 patient with external hardware (4.3 %; p = 0.25). There were 19 surgical site infections (26.4 %), 14 of which were minor infections and 5 of which were major infections. Ten internal devices (38.6 %) and 9 external devices (19.6 %) were complicated by infection (p = 0.08). Minor infections occurred in 6 internal devices (23.1 %) and 8 external devices (17.4 %; p = 0.56). Major infections occurred in 4 internal devices (15.4 %) and 1 external device (2.2 %; p = 0.05).
CONCLUSION
No significant difference was found in overall postoperative infection rate with internal and external MDO. A lower rate of major infection was observed in external devices.