Jornal de pediatria · 2020
High-resolution CT pulmonary findings in children with severe asthma.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Silva Thiago Krieger Bento da, Zanon Matheus, Altmayer Stephan, Pacini Gabriel Sartori, Watte Guilherme, Stein Renato, Pitrez Paulo Márcio, Hochhegger Bruno
Аннотация
OBJECTIVE: To compare quantitative CT parameters between children with severe asthma and healthy subjects, correlating to their clinical features.
METHODS: We retrospectively analyzed CT data from 19 school-aged children (5-17 years) with severe asthma and 19 control school-aged children with pectus excavatum. The following CT parameters were evaluated: total lung volume (TLV), mean lung density (MLD), CT air trapping index (AT%) (attenuation ≤856 HU), airway wall thickness (AWT), and percentage of airway wall thickness (AWT%). Multi-detector computed tomography (MDCT) data were correlated to the following clinical parameters: forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), forced expiratory flow at 25-75% (FEF 25-75%), FEV1/FVC ratio, sputum and bronchoalveolar lavage analysis, serum IgE levels, and previous hospitalizations due to asthma.
RESULTS: Asthma patients presented higher mean values of AT% (23.8 ± 6.7% vs. controls, 9.7 ± 3.2%), AWT (1.46 ± 0.22 mm vs. controls, 0.47 ± -735 ± 28 HU vs. controls, -666 ± 19 HU). Mean AT% was 29.0 ± 4.7% in subjects with previous hospitalization against 19.2 ± 5.0% in those with no prior hospitalization (p < 0.001). AT% presented very strong negative correlations with FVC (r = -0.933, p < 0.001) and FEV1 (r = -0.841, p < 0.001) and a moderate correlation with FEF 25-75% (r = -0.608, p = 0.007). AT% correlation with FEV1/FVC ratio and serum IgE was weak (r = -0.184, p = 0.452, and r = -0.363, p = 0.202) CONCLUSION: Children with severe asthma present differences in quantitative chest CT scans compared to healthy controls with strong correlations with pulmonary function tests and previous hospitalizations due to asthma.
METHODS: We retrospectively analyzed CT data from 19 school-aged children (5-17 years) with severe asthma and 19 control school-aged children with pectus excavatum. The following CT parameters were evaluated: total lung volume (TLV), mean lung density (MLD), CT air trapping index (AT%) (attenuation ≤856 HU), airway wall thickness (AWT), and percentage of airway wall thickness (AWT%). Multi-detector computed tomography (MDCT) data were correlated to the following clinical parameters: forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), forced expiratory flow at 25-75% (FEF 25-75%), FEV1/FVC ratio, sputum and bronchoalveolar lavage analysis, serum IgE levels, and previous hospitalizations due to asthma.
RESULTS: Asthma patients presented higher mean values of AT% (23.8 ± 6.7% vs. controls, 9.7 ± 3.2%), AWT (1.46 ± 0.22 mm vs. controls, 0.47 ± -735 ± 28 HU vs. controls, -666 ± 19 HU). Mean AT% was 29.0 ± 4.7% in subjects with previous hospitalization against 19.2 ± 5.0% in those with no prior hospitalization (p < 0.001). AT% presented very strong negative correlations with FVC (r = -0.933, p < 0.001) and FEV1 (r = -0.841, p < 0.001) and a moderate correlation with FEF 25-75% (r = -0.608, p = 0.007). AT% correlation with FEV1/FVC ratio and serum IgE was weak (r = -0.184, p = 0.452, and r = -0.363, p = 0.202) CONCLUSION: Children with severe asthma present differences in quantitative chest CT scans compared to healthy controls with strong correlations with pulmonary function tests and previous hospitalizations due to asthma.