m+Medelevator.RU
← Поиск публикаций
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2017

Infectious complications of ventricular assist device use in children in the United States: Data from the Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs).

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Auerbach Scott R, Richmond Marc E, Schumacher Kurt R, Lopez-Colon Dalia, Mitchell Max B, Turrentine Mark W, Cantor Ryan S, Niebler Robert A, Eghtesady Pirooz

Аннотация

BACKGROUND: Infections are frequent in pediatric ventricular assist device (VAD) patients. In this study we aimed to describe infections in durable VAD patients reported to Pedimacs.

METHODS: Durable VAD data from the Pedimacs registry (September 19, 2012 to December 31, 2015) were analyzed. Infections were described with standard descriptive statistics, Kaplan-Meier analysis and competing outcomes analysis.

RESULTS: There were 248 implants in 222 patients, with a mean age and a median follow-up of 11 ± 6.4 years and 2.4 patient-months (<1 day to 2.6 years), respectively. Device types were pulsatile flow (PF) in 91 (41%) patients and continuous flow (CF) in 131 (59%) patients. PF patients were younger (4 ± 4 vs 14 ± 4 years; p < 0.0001) and were more likely to have congenital heart disease (25% vs 12%; p = 0.03), prior surgery (53% vs 26%; p < 0.0001) and prior extracorporeal membrane oxygenation (24% vs 7%; p = 0.0003). Infection accounted for 17% (96 of 564) of the reported adverse events (AEs). A non-device infection was most common (51%), followed by sepsis (24%), external pump component infection (20%) and internal pump component infection (5%). Most infections were bacterial (73%) and required intravenous therapy only (77%). The risk of infection in the constant phase was higher in patients with a history of prior infection and in patients with a history of a non-infectious major AEs. Survival was lower after infection only in CF patients (p = 0.008).

CONCLUSIONS: Infection was the most common AE after pediatric VAD implantation. Non-device infections were most common. The best predictor of a future infection was a past infection. CF patients have higher risk of death after an infection.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты