MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mhn.2001.119514

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2001

Ocular motility complications after endoscopic sinus surgery with powered cutting instruments.

Bhatti M T, Giannoni C M, Raynor E, Monshizadeh R, Levine L M

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to describe 2 unique cases of ocular motility dysfunction after powered endoscopic sinus surgery and identify potential risk factors for extraocular muscle injury.

STUDY

DESIGN

Interventional case series.

RESULTS

Patient 1 developed a restrictive global ophthalmoplegia after inadvertent entry into the medial orbit during powered endoscopic sinus surgery. Patient 2 had complete loss of adduction of the left eye as a result of transection of the medial rectus muscle by a powered cutting instrument.

CONCLUSIONS

Despite advances in endoscopic sinus surgery technique and instrumentation, serious ophthalmic complications may still occur. Inadvertent entry into the medial orbital wall can result in ocular motility complications. Furthermore, it is possible that attraction of orbital contents into the tip of a powered cutting instrument may occur without significant entry into the orbital cavity.

SIGNIFICANCE: It is important for endoscopic sinus surgeons to be aware of the intimate anatomical relationship between the orbit and sinuses, as well as the potential risks of the current instruments used in endoscopic sinus surgery.

Для цитирования: Bhatti M T, Giannoni C M, Raynor E, Monshizadeh R, Levine L M. Ocular motility complications after endoscopic sinus surgery with powered cutting instruments.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2001. DOI: 10.1067/mhn.2001.119514.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.