Reconstruction of orbital floor blow-out fractures with silicone implant.

Mwanza J C, Ngoy D K, Kayembe D L

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: To evaluate the outcome of orbital floor blow-out fractures treated surgically with silicone implant.

METHODS

The patients were examined in a prospective study from October 1993 to December 1999. Over this period 11 patients were diagnosed as having orbital floor blow-out fractures. The study was restricted to those who were both treated surgically and followed-up at least three months after the discharge from hospital. Only six patients (five males and one female), ranging in age from 6 to 30 years, fulfilled the inclusion criteria. The fractures occurred during brawls in 3 patients, car accidents in 2 patients and child's play in 1 patient. The diagnosis was based on history, clinical grounds and coronal computed tomography. The surgical procedure was the same in all patients, using silicone implant to reconstruct the defects. The mean follow-up time after surgery was 4.8 months.

RESULTS

The interval between injury and diagnosis ranged from 6 to 85 days (mean: 34.8 days). Limitation of vertical eye movements was present in all 6 patients, diplopia in 4 patients, enophthalmos in 3 patients and hypoesthesia in the distribution of the infraorbital nerve in 1 patient. The mean interval time between injury and surgery was 55.3 days and the majority of the patients (83%) had late repairs (> 14 days) after injury. Postoperatively, satisfactory results were obtained with regard to limitation of vertical eye movements, diplopia, enophthalmos and hypoesthesia. Only one patient had a persistent and partially reduced enophthalmos. Silicone implant was well tolerated in all 6 cases since complications such as infection, tissue reaction and extrusion were not observed.

CONCLUSION

Satisfactory results may be obtained after late repair of orbital floor blow-out fractures. Silicone implant has the potential to be used successfully in orbital floor fractures.

Для цитирования: Mwanza J C, Ngoy D K, Kayembe D L. Reconstruction of orbital floor blow-out fractures with silicone implant.. Bulletin de la Societe belge d'ophtalmologie. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.