World neurosurgery · 2010
Placement of percutaneous thoracic pedicle screws using neuronavigation.
Клинический случайКлиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kakarla Udaya K, Little Andrew S, Chang Steve W, Sonntag Volker K H, Theodore Nicholas
Аннотация
BACKGROUND: Percutaneous thoracic pedicle screw fixation is challenging because of the complexity of the spinal anatomy and obscuration of normal surgical landmarks by soft tissue. We report a novel percutaneous technique in which intraoperative Iso-C C-arm navigation was used to treat complex thoracic spinal fractures.
METHODS: Between March and September 2007, percutaneous thoracic pedicle screw fixation was performed with the assistance of intraoperative Iso-C C-arm fluoroscopy in six patients (two males, four females; mean age=33 years, range=16-61 years) with unstable thoracic fractures. The accuracy of pedicle screw placement was assessed by postoperative computed tomography and graded according to the method of Youkilis et al.
RESULTS: Five patients had unstable acute traumatic fractures and one had an osteoporotic burst fracture. Altogether, 19 spinal segments (range=2-4/patient) were fixated using 37 pedicle screws. Pedicle screw misplacement was grade II in 16% and grade III in 3%. None of the patients had neurologic consequences due to screw misplacement, and none required conversion to an open procedure or revision of hardware. There was one wound infection.
CONCLUSION: Percutaneous thoracic pedicle screw fixation with intraoperative neuronavigation for the stabilization of complex spinal fractures is feasible and associated with acceptable rates of accuracy and morbidity.
METHODS: Between March and September 2007, percutaneous thoracic pedicle screw fixation was performed with the assistance of intraoperative Iso-C C-arm fluoroscopy in six patients (two males, four females; mean age=33 years, range=16-61 years) with unstable thoracic fractures. The accuracy of pedicle screw placement was assessed by postoperative computed tomography and graded according to the method of Youkilis et al.
RESULTS: Five patients had unstable acute traumatic fractures and one had an osteoporotic burst fracture. Altogether, 19 spinal segments (range=2-4/patient) were fixated using 37 pedicle screws. Pedicle screw misplacement was grade II in 16% and grade III in 3%. None of the patients had neurologic consequences due to screw misplacement, and none required conversion to an open procedure or revision of hardware. There was one wound infection.
CONCLUSION: Percutaneous thoracic pedicle screw fixation with intraoperative neuronavigation for the stabilization of complex spinal fractures is feasible and associated with acceptable rates of accuracy and morbidity.