DOI 10.1007/s00383-023-05536-5
Developing balloon dilatation sizing guidance for anastomotic stricture dilatation following oesophageal atresia repair.
Аннотация
PURPOSE: To develop guidance for the selection of balloon catheter size when performing an oesophageal dilatation for a stricture post oesophageal atresia repair.
METHODS
This was a single centre retrospective study at a paediatric tertiary centre. Dilatations were performed between 2015 and 2020. All dilatations were performed under general anaesthesia using balloon catheters under fluoroscopic guidance. Outliers were excluded using ROUT method and descriptive analysis was calculated to 1SD or IQR depending on the normality of data distribution.
RESULTS
97 patients underwent 341 dilatations. Median age was 19 months (37 weeks corrected gestation-17 years), median weight was 10.7 kg (2.6-72 kg). Balloon catheter sizes ranged from 6-8 mm to 18-20 mm. There was strong correlation between weight and balloon size (r = 0.8, p < 0.0001). There were 2 perforations (0.6%), both diagnosed intra-operatively and treated conservatively. From the results, weight recommendations were created for each balloon size.
CONCLUSION
Fluoroscopic balloon dilatation is a safe and effective method to treat anastomotic stricture following oesophageal atresia repair. Previous studies have shown correlation between patient weight and oesophageal diameter. We propose guidance for using an appropriate balloon size based on patient's weight with the aim to reduce complication.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.