MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4269/ajtmh.24-0620

Медицинская библиотека · The American journal of tropical medicine and hygiene · 2026

Prospective Assessment of the Performance of a Combi-Rapid Diagnostic Test to Accurately Diagnose Malaria and Detect C-Reactive Protein in Selected Settings in India.

Srivastava Bina, Anvikar Anup, Anvikar Deepali, Sharma Supriya, Ahmed Naseem, Swarnkar Deendayal, Das Manoj K, Pradhan Khageshwar, Singh Kuldeep, Eapen Alex, Kumar Sanal, Keller Thomas, Weber Stephan, Mace Aurélien, Ongarello Stefano, Dittrich Sabine, Incardona Sandra

СтатьяПеревод в очереди

Аннотация

Management of malaria-negative febrile patients is hampered by a lack of rapid diagnostic tests (RDTs) that guide treatment decisions, increasing the risks of antibiotic overuse and antimicrobial resistance. The simultaneous detection of malaria and C-reactive protein (CRP), a potentially useful host biomarker for distinguishing between bacterial and nonbacterial infections, using RDTs could help address this challenge. A prospective study was conducted at seven sites in India from April to December 2019 to evaluate the performance of the SD BIOSENSOR STANDARD™ Q Malaria/CRP Duo Test (SD BIOSENSOR, Gyeonggi-do, South Korea) against expert microscopy for malaria and against a commercial biochemistry kit for CRP, with a total of 1,799 patients with suspected malaria included in the analysis. The prevalence of malaria parasitemia according to microscopy was 13.3% (3.3% Plasmodium falciparum [P. falciparum], 10.1% Plasmodium vivax [P. vivax]). The Duo test was used to diagnose malaria, P. falciparum, and P. vivax infections, with sensitivities of 97.9% (95% CI: 95.2%-99.1%), 91.4% (95% CI: 81.4%-96.3%), and 95.0% (95% CI: 90.7%-97.3%), respectively. The Duo test performed better for detecting pan malaria and P. vivax infections compared with the routine RDT (SD BIOLINE Malaria P.f/pan antigen test; sensitivity 86.1% [95% CI: 81.1%-89.9%] and 79.9% [95% CI: 73.4%-85.1%] for malaria and P. vivax, respectively). The Duo test's sensitivity and specificity for detecting CRP at levels of 20 mg/L or higher were estimated at 87.4% (95% CI: 84.7%-89.7%) and 94.0% (95% CI: 92.4%-95.3%), respectively. The satisfactory agreement between test results and standard reference methods suggests that the test can be used in malaria-endemic settings; however, additional studies are needed to assess its impact on malaria testing and antibiotic prescription practices.

Для цитирования: Srivastava Bina, Anvikar Anup, Anvikar Deepali, Sharma Supriya, Ahmed Naseem, Swarnkar Deendayal, Das Manoj K, Pradhan Khageshwar, Singh Kuldeep, Eapen Alex, Kumar Sanal, Keller Thomas, Weber Stephan, Mace Aurélien, Ongarello Stefano, Dittrich Sabine, Incardona Sandra. Prospective Assessment of the Performance of a Combi-Rapid Diagnostic Test to Accurately Diagnose Malaria and Detect C-Reactive Protein in Selected Settings in India.. The American journal of tropical medicine and hygiene. 2026. DOI: 10.4269/ajtmh.24-0620.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.