Transcatheter closure of large atrial septal defects: feasibility and safety in a large adult and pediatric population.

Baruteau Alban-Elouen, Petit Jérôme, Lambert Virginie, Gouton Marielle, Piot Dominique, Brenot Philippe, Angel Claude-Yves, Houyel Lucile, Le Bret Emmanuel, Roussin Régine, Ly Mohamedou, Capderou André, Belli Emre

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Data are needed on the safety and efficacy of device closure of large atrial septal defects.

METHODS AND

RESULTS

Between 1998 and 2013, 336 patients (161 children <15 years) with large, isolated, secundum atrial septal defects (balloon-stretched diameter ≥34 mm in adults or echocardiographic diameter >15 mm/m(2) in children) were managed using the Amplatzer device, at the Marie Lannelongue Hospital. Transthoracic echocardiographic guidance was used starting in 2005 (n=219; 65.2%). Balloon-stretched diameter was >40 mm in 36 adults; mean values were 37.6±3.3 mm in other adults and 26.3±6.3 mm/m(2) in children. Amplatzer closure was successful in 311 (92.6%; 95% confidence interval, 89%-95%) patients. Superior and posterior rim deficiencies were more common in failed than in successful procedures (superior, 24.0% versus 4.8%; P=0.002; and posterior, 32.0% versus 4.2%; P<0.001). Device migration occurred in 4 adults (2 cases each of surgical and transcatheter retrieval); in the 21 remaining failures, the device was unreleased and withdrawn. After a median follow-up of 10.0 years (2.5-17 years), all patients were alive with no history of late complications.

CONCLUSIONS

Closure of large atrial septal defects using the Amplatzer device is safe and effective in both adults and children. Superior and posterior rim deficiencies are associated with procedural failure. Closure can be performed under transthoracic echocardiographic guidance in experienced centers. Early device migration is rare and can be safely managed by device extraction. Long-term follow-up showed no deaths or major late complications in our population of 311 patients.

Для цитирования: Baruteau Alban-Elouen, Petit Jérôme, Lambert Virginie, Gouton Marielle, Piot Dominique, Brenot Philippe, Angel Claude-Yves, Houyel Lucile, Le Bret Emmanuel, Roussin Régine, Ly Mohamedou, Capderou André, Belli Emre. Transcatheter closure of large atrial septal defects: feasibility and safety in a large adult and pediatric population.. Circulation. Cardiovascular interventions. 2014. DOI: 10.1161/circinterventions.113.001254.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.