Comparison between an adapted protocol for home and ambulatory measurement for evaluating night-time blood pressure behaviour.

Costa Borges Thamyres, Valverde de Oliveira Vitorino Priscila, Inuzuka Sayuri, Lima Sousa Ana Luiza, Martins de Oliveira Moisés, Augusto Pícoli de Andrade Carlos, Bezerra Rodrigo, Magalhães Feitosa Audes Diógenes, Barroso Weimar Kunz Sebba

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The diagnosis and treatment of hypertension rely on the accuracy of blood pressure (BP) measurements obtained both in and out of the office during awake and sleep periods.

OBJECTIVE

To evaluate whether a home blood pressure monitoring (HBPM) protocol incorporating morning, afternoon, and evening measurements supports the assessment of blood pressure behaviour during sleep and enhances the diagnosis of hypertension.

METHODS

This cross-sectional study included 40 patients (73% women; age = 62.0 ± 13.2 years) who underwent 24-h ambulatory blood pressure monitoring (ABPM) and (five-day HBPM) with measurements taken across three time periods. The association between the sleep-wake dip recorded by ABPM and the night-day difference measured by HBPM was examined. Additionally, the sensitivity, specificity, predictive values, concordance index, Kappa coefficient, and area under the ROC curve (AUC) of mean BP values obtained from HBPM were compared with those from ABPM.

RESULTS

Mean BP values obtained from HBPM were 126.2 ± 13.3/79.2 ± 9.1 mmHg, (daytime), 125.9 ± 16.4/78.7 ± 10.5 mmHg (evening), and 126.1 ± 14.3/78.9 ± 9.6 mmHg (total). For ABPM, mean values were 120.3 ± 12.5/74.5 ± 8.9 mmHg (awake), 116.5 ± 10.9/69.3 ± 8.0 mmHg (asleep), and 119.4 ± 11.4/73.4 ± 8.0 mmHg (total). Total HBPM outperformed daytime and evening HBPM in detecting abnormalities on ABPM (daytime, night-time, and 24 h), with higher sensitivity, negative predictive value (NPV), AUC, concordance index, and Kappa coefficient. The correlation between the day-night dip in ABPM and the night-day difference in HBPM was weak.

CONCLUSION

Including night-time measurements in the HBPM protocol improves the accuracy of hypertension diagnosis when compared to ABPM. However, the night-day BP difference captured by HBPM does not correspond to the day-night dip measured by ABPM.

Для цитирования: Costa Borges Thamyres, Valverde de Oliveira Vitorino Priscila, Inuzuka Sayuri, Lima Sousa Ana Luiza, Martins de Oliveira Moisés, Augusto Pícoli de Andrade Carlos, Bezerra Rodrigo, Magalhães Feitosa Audes Diógenes, Barroso Weimar Kunz Sebba. Comparison between an adapted protocol for home and ambulatory measurement for evaluating night-time blood pressure behaviour.. Blood pressure. 2025. DOI: 10.1080/08037051.2025.2514224.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.