MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.23074

Медицинская библиотека · Journal of clinical laboratory analysis · 2019

Whole-exome sequencing identified compound heterozygous variants in ROR2 gene in a fetus with Robinow syndrome.

Yang Kai, Zhu Jianjiang, Tan Ya, Sun Xiaofei, Zhao Huawei, Tang Guodong, Zhang Dongliang, Qi Hong

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Autosomal recessive Robinow syndrome (ARRS) is a rare genetic disorder, which affects the development of multiple systems, particularly the bones.

OBJECTIVES

The aim of this study was to investigate the genetic cause of a ARRS fetus and to evaluate the reliability of whole-exome sequencing (WES) in prenatal diagnosis on cases with indistinguishable multiple malformation.

METHODS

Clinical and ultrasonic evaluations were conducted on the fetus, and multiplatform genetic techniques were used to identify the variation responsible for RS. The pathogenicity of the novel variation was evaluated by in silico methods. Western blotting (WB) and immunohistochemistry (IHC) were performed on fetal tissues after the fetus' stillbirth and postabortal autopsy.

RESULTS

A compound heterozygous variation consisting c.613C > T and c.904C > T in ROR2 gene was identified. In silico prediction suggested that c.904C > T was a deleterious variant. IHC result demonstrated that ror2 expression level of the proband in osteochondral tissue significantly increased comparing with that of the control sample.

CONCLUSIONS

For the first time in Chinese population, we characterized a novel variation in ROR2 gene causing ARRS. This study extended the mutation spectrum of ARRS and provided a promising strategy for prenatal diagnosis of cases with ambiguous multiple deformities.

Для цитирования: Yang Kai, Zhu Jianjiang, Tan Ya, Sun Xiaofei, Zhao Huawei, Tang Guodong, Zhang Dongliang, Qi Hong. Whole-exome sequencing identified compound heterozygous variants in ROR2 gene in a fetus with Robinow syndrome.. Journal of clinical laboratory analysis. 2019. DOI: 10.1002/jcla.23074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.