MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2025.05.015

Медицинская библиотека · American heart journal · 2025

Systolic performance of the single ventricle, exercise capacity, and endothelial function in pediatric Fontan patients.

Gallegos Flora Nuñez, Bernstein Daniel, Punn Rajesh, Long Jin, Stauffer Katie Jo, Thorson Kelly, Chen Sharon, Lui Mavis C, Olson Inger, Myers Jonathan, Palaniappan Latha, Tierney Seda

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

By age 40, roughly half of the individuals with Fontan circulation will have died or undergone heart transplantation. Poor exercise capacity and endothelial dysfunction accelerate disease progression.

OBJECTIVE

This study aims to assess the systolic function of the single ventricle (SV) in pediatric Fontan patients entering an exercise intervention (RE-ENERGIZE FONTAN) and how it is associated with exercise capacity and endothelial function.

METHODS

This cohort comes from an ongoing randomized trial in Fontan patients, using live video conferencing for supervised exercise. Participants (ages 8-19) cleared for exercise underwent 2D/3D echocardiograms, cardiopulmonary testing, and endothelial function (RHI). 2D longitudinal strain (LS, right ventricle), 2D global longitudinal strain (GLS, left ventricle), and circumferential strain were measured with TomTec, and 3D ejection fraction (3D-EF) and 3D-GLS were calculated.

RESULTS

We have enrolled 114 Fontan patients. Median age was 12.7 years (IQR 10.2, 15.6). The median time from Fontan operation was 8.8 years (IQR 6.2, 12.0). Fifty-seven patients (50%) had a single right ventricle. SV systolic performance measures were: 2D-LS/GLS -15.6% ± 4.19%, circumferential strain was -18.7% ± 6.83%, 3D-EF 49.9% ± 7.26%, and 3D-GLS -16.8% ± 4.37%. Peak VO2 was 1,290 ± 502 mL/min, and percent predicted peak VO2 was 67.8% ± 15.6%. RHI was 1.44 ± 0.576. 2D-LS/GLS and 3D EF correlated with percent predicted peak VO2 (R = -0.28, P = .007 and R = 0.24, P = .019). 3D-EF correlated positively with RHI (R = 0.29, P = .0071).

CONCLUSIONS

In this cohort of pediatric Fontan patients, SV systolic function was diminished at baseline, and there was a direct correlation between 2D strain and 3D-EF with percent predicted peak VO2, and additionally, 3D-EF with endothelial function.

CLINICAL TRIAL NUMBER: NCT04195451.

Для цитирования: Gallegos Flora Nuñez, Bernstein Daniel, Punn Rajesh, Long Jin, Stauffer Katie Jo, Thorson Kelly, Chen Sharon, Lui Mavis C, Olson Inger, Myers Jonathan, Palaniappan Latha, Tierney Seda. Systolic performance of the single ventricle, exercise capacity, and endothelial function in pediatric Fontan patients.. American heart journal. 2025. DOI: 10.1016/j.ahj.2025.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.