MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/ice.2026.10476

Медицинская библиотека · Infection control and hospital epidemiology · 2026

Impact of copper-coated surfaces on healthcare-associated infections and microbial load in a pediatric tertiary care setting: an observational cohort study.

Michalchuk Quentin, Zhang Qian, Collet Jun C, Piasecki Susanna, Walker Celia, Wong Titus, Goldfarb David M, Srigley Jocelyn A

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of copper-coated high-touch surfaces on environmental microbial burden and healthcare-associated infection (HAI) rates.

DESIGN

Observational cohort study over 20 months.

SETTING

Pediatric intensive care and oncology inpatient units in a tertiary care hospital.

PARTICIPANTS

All patients admitted to rooms with or without copper-coated surfaces.

EXPOSURE: Spray-on copper coating applied to high-touch surfaces in patient rooms.

METHODS

Patients were admitted to rooms according to routine hospital practices. Demographic and clinical data were collected for a subset of patients admitted to rooms with copper-coated surfaces and matching control rooms. Environmental samples were collected from high-touch surfaces to quantify bacterial colony counts. HAIs were identified via a surveillance database and reported per 10,000 patient days. Poisson regression and negative binomial mixed-effects model were used for analysis.

RESULTS

Patients in copper-coated rooms were more likely to have an infection on admission (29.7% vs 2.9%; P = .003). Bacterial colony counts trended lower in copper-coated rooms (rate ratio (RR) 0.74, 95% CI 0.50-1.08; P = .11; absolute rate difference -12.25, 95% CI -26.12-2.10), with variability by surface type. HAI rates trended higher in copper-coated rooms compared to control rooms (48.2 vs 30.5 per 10,000 patient days; RR 1.58, 95% CI 0.78-3.20; P = .20).

CONCLUSIONS

Copper-coated surfaces were not associated with statistically significant reductions in microbial burden or HAI rates. Contributing factors may include low baseline microbial load, low baseline HAI rates, variable copper alloy efficacy, short study duration, and differences between patients in intervention and control rooms.

Для цитирования: Michalchuk Quentin, Zhang Qian, Collet Jun C, Piasecki Susanna, Walker Celia, Wong Titus, Goldfarb David M, Srigley Jocelyn A. Impact of copper-coated surfaces on healthcare-associated infections and microbial load in a pediatric tertiary care setting: an observational cohort study.. Infection control and hospital epidemiology. 2026. DOI: 10.1017/ice.2026.10476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.