MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2016.05.015

Медицинская библиотека · The Annals of thoracic surgery · 2016

Mechanical Circulatory Support as Bridge to Transplantation for the Failing Single Ventricle.

Arnaoutakis George J, Blitzer David, Fuller Stephanie, Eckhauser Aaron W, Montenegro Lisa M, Rossano Joseph W, Gaynor J William

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Circulatory failure necessitating cardiac transplantation will ultimately develop in many patients with functional single-ventricle physiology. Interest in the use of mechanical circulatory support (MCS) in this population is growing.

METHODS

This was a retrospective case series of patients with functional single-ventricle physiology who underwent MCS with a ventricular assist device or a total artificial heart as a bridge to cardiac transplantation between January 2006 and December 2014. Baseline demographics, intraoperative data, postoperative complications, and outcome data were collected from the medical record.

RESULTS

MCS was used in 5 patients: HeartWare ventricular assist device (HeartWare International, Framingham, MA) in 1 patient, SynCardia total artificial heart (SynCardia Systems, Tucson, AZ) in 1, Thoratec Paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, CA) in 1, and the Berlin Heart EXCOR (Berlin Heart Inc, The Woodlands, TX) in 2. The mean age at MCS was 12 ± 8 years. There were 2 early deaths at 12 and 28 days after MCS: 1 patient died of multiorgan system failure and 1 of neurologic injury. Overall, neurologic complications occurred in 3 patients (60%), and 1 patient (20%) required renal replacement therapy. Three patients (60%) underwent successful cardiac transplantation. The median time on the waiting list was 59 days (interquartile range, 18 to 126 days), and the median duration of MCS was 60 days (interquartile range, 28 to 93 days). At the time of transplant, all 3 patients were ambulatory, without the need for mechanical ventilation, and end-organ dysfunction had resolved. The 3 patients who received transplants were discharged from the hospital and were alive at an average follow-up of 9 ± 14 months.

CONCLUSIONS

MCS can be successfully used as a bridge to transplantation in patients with a failing single-ventricle circulation. Use of MCS can allow for resolution of end-organ dysfunction and rehabilitation, leading to improved outcomes in this difficult population.

Для цитирования: Arnaoutakis George J, Blitzer David, Fuller Stephanie, Eckhauser Aaron W, Montenegro Lisa M, Rossano Joseph W, Gaynor J William. Mechanical Circulatory Support as Bridge to Transplantation for the Failing Single Ventricle.. The Annals of thoracic surgery. 2016. DOI: 10.1016/j.athoracsur.2016.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.