Strategies for tricuspid re-repair in Ebstein malformation using the cone technique.

Dearani Joseph A, Said Sameh M, Burkhart Harold M, Pike Roxann B, O'Leary Patrick W, Cetta Frank

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Successful tricuspid repair for Ebstein malformation (EM) is challenging. Cone repair has recently emerged as the most anatomic repair technique. There are no data on tricuspid re-repair in EM. We reviewed our experience with tricuspid valve (TV) re-repair using a cone technique.

METHODS

Between June 2007 and October 2012, 134 patients underwent cone repair. Prior TV repair was performed in 20 patients (10 female, 50%). Median age was 15 years (range, 4 to 68 years). Four patients (20%) had prior bidirectional cavopulmonary anastomosis (BDCPA). Preoperative heart failure was present in 8 patients (40%). Recurrent tricuspid regurgitation (TR) was due to incomplete leaflet coaptation with tethered anterior leaflet in all patients; and 10 patients (50%) had diminutive septal leaflet. Prior repair techniques consisted of annuloplasty maneuvers in all patients with no or incomplete surgical delamination in all patients.

RESULTS

The TV re-repair using cone technique was possible in all patients. Plication of atrialized right ventricle was done in 6 patients (30%). Modifications included annuloplasty band in 16 patients (80%) and TV leaflet augmentation in 8 (40%). The BDCPA was performed in 3 patients (15%) and modified Cox-maze procedure was done in 10 (50%). There were no mortalities or reoperations. Mean follow-up was 7.7 ± 10.7 months; during follow-up, 18 patients had no or mild TR and 2 had moderate TR.

CONCLUSIONS

TV re-repair in EM using the cone technique is feasible, particularly when there has been no surgical leaflet delamination at initial operation. Leaflet augmentation facilitates and annuloplasty band stabilizes a competent TV re-repair. Longer follow-up is required to assess durability.

Для цитирования: Dearani Joseph A, Said Sameh M, Burkhart Harold M, Pike Roxann B, O'Leary Patrick W, Cetta Frank. Strategies for tricuspid re-repair in Ebstein malformation using the cone technique.. The Annals of thoracic surgery. 2013. DOI: 10.1016/j.athoracsur.2013.02.067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.