MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5005/jp-journals-10024-1092

Медицинская библиотека · The journal of contemporary dental practice · 2012

Comparison of reproducibility of natural head position using two methods.

Khan Abdul Rahim, Rajesh R N G, Dinesh M R, Sanjay N, Girish K S, Venkataraghavan Karthik

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

UNLABELLED: Lateral cephalometric radiographs have become virtually indispensable to orthodontists in the treatment of patients. They are important in orthodontic growth analysis, diagnosis, treatment planning, monitoring of therapy and evaluation of final treatment outcome.

AIM: The purpose of this study was to evaluate and compare the maximum reproducibility with minimum variation of natural head position using two methods, i.e. the mirror method and the fluid level device method.

MATERIALS AND

METHODS

The study included two sets of 40 lateral cephalograms taken using two methods of obtaining natural head position: (1) The mirror method and (2) fluid level device method, with a time interval of 2 months. Inclusion criteria • Subjects were randomly selected aged between 18 to 26 years Exclusion criteria • History of orthodontic treatment • Any history of respiratory tract problem or chronic mouth breathing • Any congenital deformity • History of traumatically-induced deformity • History of myofacial pain syndrome • Any previous history of head and neck surgery.

RESULTS

The result showed that both the methods for obtaining natural head position-the mirror method and fluid level device method were comparable, but maximum reproducibility was more with the fluid level device as shown by the Dahlberg's coefficient and Bland-Altman plot. The minimum variance was seen with the fluid level device method as shown by Precision and Pearson correlation.

CONCLUSION

The mirror method and the fluid level device method used for obtaining natural head position were comparable without any significance, and the fluid level device method was more reproducible and showed less variance when compared to mirror method for obtaining natural head position.

CLINICAL SIGNIFICANCE: Fluid level device method was more reproducible and shows less variance when compared to mirror method for obtaining natural head position.

Для цитирования: Khan Abdul Rahim, Rajesh R N G, Dinesh M R, Sanjay N, Girish K S, Venkataraghavan Karthik. Comparison of reproducibility of natural head position using two methods.. The journal of contemporary dental practice. 2012. DOI: 10.5005/jp-journals-10024-1092.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.