m+Medelevator.RU
← Поиск публикаций
Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia · 2025

Real-world performance evaluation of a telemonitoring system for Parkinson's disease symptom assessment.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kosmidi Eleni, Kanellos Foivos S, Xiromerisiou Georgia A, Chondrogiorgi Maria, Rigas Georgios, Katsenos Andreas P, Simos Yannis V, Peschos Dimitrios, Konitsiotis Spyridon, Tsamis Konstantinos I

Аннотация

BACKGROUND: Parkinson's disease (PD) nurses constitute a reliable modality for appraising the motor status of patients, second only to expert neurologists. Consequently, employing PD nurses for the assessment of medical device performance is appreciated to be a fundamental benchmark in the field.

OBJECTIVE: To evaluate the precision of a telemonitoring device in measuring motor symptoms when utilized at patient's home during everyday life conditions.

METHODS: To ascertain the extent of correlation between device-reported outcomes and PD nurse assessments and the precision with which the device detects symptoms such as gait impairment, rest tremor, bradykinesia, and the presence of OFF, a total of 34 evaluations were conducted by a PD nurse at the patients' home, each lasting 3 h.

RESULTS: A robust correlation was noted for all three symptoms when analyzed at both 30-minute intervals and cumulatively over the entire 3-hour duration with Pearson's r range 0.68-0.76 and 0.83-0.90 respectively. Furthermore, substantial agreement was observed for the identification of the presence of all three symptoms with Cohen's kappa range from 0.61 to 0.71 across all 30-minute evaluations. Finally, the device demonstrates high accuracy in detecting rest tremor (90%), bradykinesia (89%), gait impairment (95%) and OFF state (94%).

CONCLUSION: This study evaluates for the first time the performance of a remote monitoring device, unobtrusively, at patients familiar environment, with a PD nurse present in non-scripted scenarios. The device exhibited commendable efficacy in the accurate detection of PD symptoms and state.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты