MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.175.6.1751557

Медицинская библиотека · AJR. American journal of roentgenology · 2000

Glossoptosis (posterior displacement of the tongue) during sleep: a frequent cause of sleep apnea in pediatric patients referred for dynamic sleep fluoroscopy.

Donnelly L F, Strife J L, Myer C M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the frequency of glossoptosis (posterior displacement of the tongue) as a cause of sleep apnea in pediatric patients referred for fluoroscopic sleep studies.

MATERIALS AND

METHODS

Seventy consecutive dynamic fluoroscopic sleep studies performed to evaluate sleep apnea were reviewed. All patients had been sedated and examined with lateral fluoroscopy during sleep. Anatomic changes in the airway were correlated with episodes of oxygen desaturation. Cases of glossoptosis, in which the tongue moved posteriorly during sleep and abutted the posterior pharynx, resulting in airway obstruction and oxygen desaturation, were identified. Associated factors were reviewed.

RESULTS

Of 70 sleep studies reviewed, glossoptosis was the cause of airway obstruction in 17 patients (24%). Mean age in these 17 patients was 3 years (range, 5 days to 13 years). Seven of the 17 children were younger than 1 year old. Only three patients had no underlying medical problems. Four patients had macroglossia (Down syndrome, n = 3; duplicated tongue, n = 1) as a cause, and three patients had micro- or retrognathia (Pierre Robin syndrome, n = 2; Rubinstein-Taybi syndrome, n =1) as a cause. Six patients had neuromuscular abnormalities.

CONCLUSION

Glossoptosis was a cause of airway obstruction in 25% of pediatric patients referred for fluoroscopic sleep studies. Attention to this anatomic region is important when evaluating children with sleep apnea.

Для цитирования: Donnelly L F, Strife J L, Myer C M. Glossoptosis (posterior displacement of the tongue) during sleep: a frequent cause of sleep apnea in pediatric patients referred for dynamic sleep fluoroscopy.. AJR. American journal of roentgenology. 2000. DOI: 10.2214/ajr.175.6.1751557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.