MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(85)90237-1

Медицинская библиотека · The American journal of cardiology · 1985

Accuracy of two-dimensional echocardiography in the diagnosis of congenital heart disease.

Gutgesell H P, Huhta J C, Latson L A, Huffines D, McNamara D G

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

To assess the accuracy of 2-dimensional (2-D) echocardiography in the evaluation of cardiac anatomy in patients with congenital heart disease, 2-D echocardiograms were performed in 126 infants and children before cardiac catheterization and angiocardiography. The segmental echocardiographic analysis included determination of intracardiac, great artery, systemic venous and pulmonary venous anatomy. The 126 patients had 259 separate cardiovascular abnormalities, of which 226 (87%) were prospectively identified by 2-D echocardiography. There were 8 false-positive diagnoses. The most common lesions and the sensitivity and specificity of echocardiography were: patent ductus arteriosus, 41 patients (83% and 100%, respectively), ventricular septal defect, 35 patients (86% and 100%); atrial septal defect, 26 patients (85% and 99%); pulmonary valve stenosis, 25 patients (77% and 97%), transposition of the great arteries, 16 patients (100% and 100%); and total anomalous pulmonary venous connection, 14 patients (85% and 100%). Less common defects and their rate of detection included coarctation of the aorta, 10 of 12 patients; atrioventricular canal, 10 of 10 patients; tetralogy of Fallot, 10 of 10 patients; aortic valve stenosis 8 of 8 patients; right aortic arch, 8 of 8 patients; interrupted aortic arch, 4 of 4 patients; and unilateral pulmonary vein atresia, 0 of 1 patient. In 33 patients (26%), the errors in echocardiographic analysis were judged to have surgical importance. Most errors were the result of overlooking or misinterpreting data that had been appropriately recorded on videotape. Pulmonary valve stenosis and patent ductus arteriosus are the lesions most likely to be misdiagnosed by ultrasound studies relying on imaging alone.

Для цитирования: Gutgesell H P, Huhta J C, Latson L A, Huffines D, McNamara D G. Accuracy of two-dimensional echocardiography in the diagnosis of congenital heart disease.. The American journal of cardiology. 1985. DOI: 10.1016/0002-9149(85)90237-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.