MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.m.00067

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2014

Comparison of functional outcome scores in radial polydactyly.

Dijkman Robert R, van Nieuwenhoven Christianne A, Selles Ruud W, Hovius Steven E R

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A wide range of outcome assessment systems have been used to describe the results and evaluate residual impairment after surgery for radial polydactyly. We conducted a study to determine which of these assessment systems should be considered superior for the most common types of radial polydactyly (types II and IV).

METHODS

Ten outcome assessment systems were selected. Three examiners independently evaluated thirty-seven patients, aged four to twenty-two years, with radial polydactyly. Patients completed two manual activity questionnaires. Interobserver reliability was determined with use of an intraclass correlation coefficient (ICC). Validity was assessed by correlating the results derived with the outcome assessment systems with functional visual analog scale (VAS), aesthetic VAS, and manual activity questionnaire scores.

RESULTS

Thirty-seven patients (forty-one hands with radial polydactyly) were evaluated. All patients were assessed by at least two examiners. Reliability was highest for the Japanese Society for Surgery of the Hand (JSSH), Cheng et al., and Tada et al. assessment systems (overall ICCs ≥ 0.70). The JSSH system had the highest overall correlations (rs ranging from 0.48 to 0.80 and 0.45 to 0.63) with functional and aesthetic VAS scores. No significant correlations were found between the outcome scores and the results of the manual activity questionnaires after an average follow-up time of 112 months.

CONCLUSIONS

Interobserver reliability was highest for the JSSH classification, which also showed superior correlations with both examiner-rated and patient-rated VAS scores for functional and aesthetic outcome compared with the other nine assessment systems. The finding of a poor correlation between the outcome scores and the results of manual activity questionnaires is in agreement with findings in published literature. We recommend the JSSH assessment method for the scientific evaluation of the outcomes, in terms of body structure and function, of the treatment of radial polydactyly.

Для цитирования: Dijkman Robert R, van Nieuwenhoven Christianne A, Selles Ruud W, Hovius Steven E R. Comparison of functional outcome scores in radial polydactyly.. The Journal of bone and joint surgery. American volume. 2014. DOI: 10.2106/jbjs.m.00067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.